Setting the end point of measuring range (only for 1-axis devices)
Short pin 5 to pin 1 for 2…8 s.
a
The green LED flashes at a frequency of 1 Hz.
Position the sensor at the end point of the measuring range.
Short pin 5 to pin 1 for 14…20 s.
a
The yellow CENTER LED flashes at a frequency of 4 Hz. The green LED lights up for 2 s. The
device then returns to the activated teach-in process.
Default setting
Short pin 5 to pin 1 for 8…14 s.
a
The green LED flashes at a frequency of 2 Hz.
Short pin 5 to pin 1 for 2…8 s.
a
The yellow CENTER LED flashes at a frequency of 1 Hz. The green LED lights up for 2 s. The
device then returns to the activated teach-in process.