background image

V01.00 | 2022/02

13

4.5

Technical accessories

Dimension drawing

Type

ID

Description

41

24

54

M12 × 1

16

USB-Mini

IN-DC

LED:
CH1 (C/Q)
CH2 (DI/DO)
Error

LED: PWR

USB-2-
IOL-0002

6825482

IO-Link adapter V1.1 with 
integrated USB interface

14

42

11.5

ø 15

M12 x 1

L

14

M12 x 1

ø 15

49.5

18.2

RKC5.301T-1
.5-RSC4T/
TXL320

6625005

Adapter cable (for connecting
the sensor to the USB-2-IOL-0002
IO-Link adapter and other
devices), M12 female connector,
straight, 5-pin, M12 male 
connector, straight, 3-pin, cable
length: 1.5 m; jacket material:
PUR, black; cULus approval, RoHS
compliant, protection class IP67,
see 

www.turck.com

42

11.5

ø 15

M12 x 1

L

M12 x 1

ø 15

49.5

18.2

RKC4.4T-2-
RSC4.4T/TXL

6625608

Connection cable, M12 female
connector, straight, 4-pin, M12
male connector, straight, 4-pin,
cable length: 2 m, jacket mater-
ial: PUR, black; cULus approval;
other cable lengths and versions
available, see 

www.turck.com

42

11.5

ø 15

M12 x 1

L

50

5

RKC4.4T-2/
TXL

6625503

Connection cable, M12 female
connector, straight, 4-pin, cable
length: 2 m, jacket material: PVC,
black; cULus approval; 
other cable lengths and versions
available, see 

www.turck.com

Содержание B N Series

Страница 1: ...Your Global Automation Partner Instructions for Use B N QR20 2L Inclinometers with Two Analog Outputs...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 3: ...Indication elements 9 4 2 Properties and features 9 4 3 Operating principle 9 4 4 Functions and operating modes 10 4 4 1 Setting options 10 4 4 2 Output behavior 10 4 4 3 Measurement axes 12 4 5 Techn...

Страница 4: ...rck com 14 Technical data 24 14 1 Technical data B1N QR20 2L 24 14 2 Technical data B2N QR20 2LI2X3 H1151 26 14 3 Technical data B2N QR20 2LUX3 H1151 28 14 4 Technical data B2NF QR20 2LI2X3 H1151 30 1...

Страница 5: ...s a dangerous situation with medium risk of death or severe injury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avo...

Страница 6: ...360 Functional principle B1N Static inclinometer uniaxial accelero meter cell B1NF Dynamic inclino meter uniaxial accelerometer cell and gyroscope B2N Static inclinometer biaxial accelero meter cell B...

Страница 7: ...sis to the commissioning of your applic ation The Turck product database under www turck com contains software tools for program ming configuration or commissioning data sheets and CAD files in numero...

Страница 8: ...The devices may only be used as described in these instructions Any other use is not in accord ance with the intended use Turck accepts no liability for any resulting damage 3 2 Obvious misuse n The d...

Страница 9: ...with a green and two yellow LEDs The green LED indicates the operating voltage and the device status The yellow LEDs are lit when the spirit level function is active 4 2 Properties and features n Angl...

Страница 10: ...increase to indicate a clockwise rotation 4 4 1 Setting options The devices have an IO Link interface and can be configured using the USB 2 IOL 0002 IO Link adapter via an FDT frame e g PACTware The...

Страница 11: ...an inverted value of the inclination angle is also output via the second analog output For 2 axis devices one axis is transmitted for each analog output The following output configurations can be set...

Страница 12: ...is of the 1 axis inclinometers covers the angle range from 0 359 9 Fig 3 One measurement axis The 2 axis inclinometers cover the angle range of 85 on two axes in all directions This results in an unme...

Страница 13: ...male connector straight 3 pin cable length 1 5 m jacket material PUR black cULus approval RoHS compliant protection class IP67 see www turck com 42 11 5 15 M12 x 1 L M12 x 1 15 49 5 18 2 RKC4 4T 2 RSC...

Страница 14: ...echnical accessories 14 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Dimension drawing Type ID Description 60 30 50 20 M12 x 1 M12 x 1 42 5 15 4 5 8 TX1 Q20L60...

Страница 15: ...ave no mutual effect on angle measurement The maximum tightening torque of the screws is 3 Nm Clean the installation surface and the surrounding area Position the potted side of the device on an even...

Страница 16: ...sor Connect the open end of the connection cable to the power supply and or processing units 6 1 Wiring diagrams Wiring diagram B1N QR20 2L 4 BK 1 BN 3 BU 2 WH 5 GY 1 5 3 2 4 teach IOL outcw outccw Fi...

Страница 17: ...n the inclinometer is aligned The two yellow LEDs are lit when the position of the inclinometer is within a window of 0 5 around the center The LEDs flash at an increasing frequency the closer the sen...

Страница 18: ...ncy Spirit level function moving away from midpoint 8 2 LED indicators B2N LED Color Meaning PWR IOL Green Device is operational Flashes green FDT IODD communication active X Center Yellow Spirit leve...

Страница 19: ...n is activated by default Rotation direction The function can set the rotation direction of the axis or axes With the default setting the analog values of the sensors increase to indicate a clockwise...

Страница 20: ...ating the teach in process Bridge pin 5 with pin 1 before switching on the supply voltage Switch on the supply voltage and immediately release the bridge a The teach in process is active when the gree...

Страница 21: ...pin 1 for 14 20 s a The yellow CENTER LED flashes at a frequency of 4 Hz The green LED lights up for 2 s The device then returns to the activated teach in process Default setting Short pin 5 to pin 1...

Страница 22: ...the device does not function as expected first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no...

Страница 23: ...evice to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloade...

Страница 24: ...ion 0 2 0 15 0 2 0 15 Temperature drift 0 006 K Electrical data Operating voltage 15 30 VDC Ripple 10 Uss Insulation test voltage 0 5 kV Short circuit protection Yes Wire breakage reverse polarity pro...

Страница 25: ...51 Type of protection IP68 IP69K MTTF 297 years acc to SN 29500 ed 99 40 C Operating voltage indication 1 LED green Measuring range indication 2 LED yellow The repetition accuracy linearity deviation...

Страница 26: ...5 0 35 0 3 Temperature drift 0 1 K 0 04 K 0 025 K 0 02 K 0 012 K Electrical data Operating voltage 15 30 VDC Ripple 10 Uss Insulation test voltage 0 5 kV Short circuit protection Yes Wire breakage re...

Страница 27: ...H QR20 2LI2X3 H1151 B2N60H QR20 2LI2X3 H1151 B2N85H QR20 2LI2X3 H1151 Measuring range indication 2 LED yellow The repetition accuracy linearity deviation and temperature drift values apply to the incl...

Страница 28: ...0 35 0 3 Temperature drift 0 1 K 0 04 K 0 025 K 0 02 K 0 012 K Electrical data Operating voltage 15 30 VDC Ripple 10 Uss Insulation test voltage 0 5 kV Short circuit protection Yes Wire breakage rever...

Страница 29: ...H QR20 2LUX3 H1151 B2N60H QR20 2LUX3 H1151 B2N85H QR20 2LUX3 H1151 Measuring range indication 2 LED yellow The repetition accuracy linearity deviation and temperature drift values apply to the inclina...

Страница 30: ...y deviation 0 5 0 5 0 4 0 3 0 25 Temperature drift 0 1 K 0 04 K 0 025 K 0 02 K 0 012 K Electrical data Operating voltage 15 30 VDC Ripple 10 Uss Insulation test voltage 0 5 kV Short circuit protection...

Страница 31: ...H QR20 2LI2X3 H1151 B2NF60H QR20 2LI2X3 H1151 B2NF85H QR20 2LI2X3 H1151 Measuring range indication 2 LED yellow The repetition accuracy linearity deviation and temperature drift values apply to the in...

Страница 32: ...eviation 0 5 0 5 0 4 0 3 0 25 Temperature drift 0 1 K 0 04 K 0 025 K 0 02 K 0 012 K Electrical data Operating voltage 15 30 VDC Ripple 10 Uss Insulation test voltage 0 5 kV Short circuit protection Ye...

Страница 33: ...5H QR20 2LUX3 H1151 B2NF60H QR20 2LUX3 H1151 B2NF85H QR20 2LUX3 H1151 Measuring range indication 2 LED yellow The repetition accuracy linearity deviation and temperature drift values apply to the incl...

Страница 34: ...S A S 11 rue de Courtalin Bat C Magny Le Hongre F 77703 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckb...

Страница 35: ...w turck ru Sweden Turck Sweden Office Fabriksstr ket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Sing...

Страница 36: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100036883 2022 02 100036883...