Rigging Manual
37
9.0.1 Required Components
Item
Quantity
TBV118L Subwoofer
2 (maximum)
TBV123 Cabinet
2 (maximum)
Item
Length
TPole 60
60 cm
TPole 90
90 cm
TPole 120
120 cm
9.0.2 Location
The TBV118L subwoofer should be located on a flat, horizontal, and dry surface,
capable of supporting the weight of the complete assembly.
9.0.3 Measured Weights
Please see Section 2.3 Weights on Page 9, and refer to EASE Focus Rigging
Parameters when designing your system.
Chapter 9: Pole Mounting a TBV123 Cabinet on a TBV118L Subwoofer
The following procedure describes how to pole mount a TBV123 cabinet onto a
TBV118L Subwoofer.
The subwoofer has a top panel M20 thread mount receptacle that can accept an
optional distance rod accessory and the TBV123 has two pole mount receptacles
underneath that allow it to be mounted at two different angles for
best coverage.
The M20 distance rods are available in three different lengths:
60, 90, and 120 cm.
A second TBV123 cabinet may be added on top of the first cabinet and secured
using the integral mounting links and rigging pins. No tools are required.
!
!
WARNING
DO NOT EXCEED A TOTAL QUANTITY OF 2 TVB123 AND 2 TBV118L CABINETS FOR
THIS GROUND STACK CONFIGURATION. FAILURE TO FOLLOW INSTRUCTIONS MAY
CAUSE PERMANENT INJURY OR DEATH.
!
!
WARNING
FOR GROUND STACKED CONFIGURATIONS OF 2 TBV123 CABINETS PLUS 1 OR
2 TBV118L SUBWOOFERS, THE STACKED SYSTEM MUST BE SECURED TO THE
STACKING PLATFORM USING RATCHET STRAPS OR GUY WIRES. FAILURE TO FOLLOW
INSTRUCTIONS MAY CAUSE PERMANENT INJURY OR DEATH.
9.0.4 Personnel
The following procedures shall be undertaken by experienced, certified,
qualified, and authorised personnel only. The procedures require the use of
three or more authorised persons.
Protective Headwear shall be worn
Protective Footwear shall be worn
Protective Gloves shall be worn
Protective Eyewear shall be worn
Practice Safe Lifting