Rigging Manual
25
Chapter 5: Assembling a Mixed Array on a TBV123-FB Flybar
5.0.1 Required Components
Item
Quantity
TBV123-FB Flybar
1
TBV118L Subwoofer
1 (maximum)
TBV123 Cabinet
2 (maximum)
5.0.2 Preparation
Use the EASE FOCUS II software application to design your system to suit the
venue. This will calculate which flybar mounting hole to attach your bow shackle.
5.0.3 Location
Move the TBV118L subwoofer cabinet so it is sitting upright on a safe flat surface,
directly below the suspension point.
5.0.4 Measured Weights
Please see Section 2.3 Weights on Page 9, and refer to EASE Focus Rigging
Parameters when designing your system.
TBV123-FB Flybar Working Load Limit (WLL)
Item
Working Load Limit (WLL)
TBV123-FB
100 kg
220.5 lbs
The following procedure shows how to build a mixed array of one TBV118L
subwoofer and 2 TBV123 cabinets.
The system is flown using a TBV123-FB flybar that attaches to your
lifting system.
The TBV118L subwoofer connects to the mounting points on the flybar. The top
TBV123 cabinet connects to the subwoofer above using the integral mounting
points and rigging pins. No tools are required.
!
!
WARNING
DO NOT EXCEED A TOTAL QUANTITY OF 1 TBV118L SUBWOOFER AND 2 TBV123
CABINETS FOR 1 TBV123-FB FLYBAR. FAILURE TO FOLLOW INSTRUCTIONS MAY
CAUSE PERMANENT INJURY OR DEATH.
!
!
WARNING
THIS ARRAY SHALL ONLY BE MADE WITH THE TBV118L SUBWOOFER ON TOP, AND
THE TBV123 CABINETS BELOW. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE
PERMANENT INJURY OR DEATH.
5.0.5 Personnel
The following procedures shall be undertaken by experienced, certified,
qualified, and authorised personnel only. The procedures require the use of three
or more authorised persons.
Protective Headwear shall be worn
Protective Footwear shall be worn
Protective Gloves shall be worn
Protective Eyewear shall be worn
Practice Safe Lifting