![Tunze SmartController 7000 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/tunze/smartcontroller-7000/smartcontroller-7000_instructions-for-use-manual_1180663022.webp)
4
3
2
1
SmartController
7000
22
H
ig
h T
ec
h A
qu
ar
iu
m
Ec
ol
og
y
Menu “Measurement”
Connect the SmartController 7000 to the mains adapter
5012.010 as the power supply, and then connect to the power
grid (1).
Open the SmartController 7000 page in the browser and select
a language (2a).
After clicking on the menu item “Measurement” (2b) the menu
“Measuring and switching sockets” (3) will be displayed.
In this menu, the left field is for the pH or mV settings (4), the
right field for the temperature settings (5).
Field “pH / mV settings”
(4):
Function “mV” (6a):
The current redox value will be displayed (7). By activating this
function, the
channel
4
of the SmartController 7000 (8) will
be activated as mV controller, and controlled according to a
specified value.
The mV electrode 7055.100 (9) can be corrected / adjusted
with the Redox Test So475 mV, 50 ml (1.7 oz.) 7075.150
(10) and the displayed mV value with the lowest function of the
field (11).
Function “pH” (6b):
The current pH value will be shown (12). By activating this
function, the
channel
4
of the SmartController 7000 (8) will
be activated as pH controller, and controlled according to a
specified value.
In this field it is also possible to perform the calibration pH 5 /
7 or 7 / 9 (13) or resp. to test the electrode (14).
At the bottom in this field (15) the pH value for a measured
KH value (carbonate hardness of water) can be calculated
automatically in the freshwater aquarium and for an optimum
CO
2
level. In an average freshwater aquarium, the CO
2
levels
should between 10-25 mg/l, and 25-40 mg/l CO
2
in case of a
strong lighting (at least 0.5 W/l (W/USgal.)).