Caution!
Only turn on the control for temperature, pH or mV (see
chapter “Measurement menu”, page 21), if a switching socket
(Controlled Power Socket) (3) or a valve (4) is plugged in to the
corresponding connector socket.
When directly connecting a pump to a socket (
channel 1-4
)
(5) of the SmartController 7000 with the controller for a
switching socket or a valve switched on, the pump will stop
running.
If the pump was connected to the switching socket or the
valve, the control of both devices will be possible.
Access to the
SmartController
via the Internet
(web interface)
In order to reach the SmartController 7000 outside of the in-
house WiFi network, an external access to the router must
be enabled. For example, this can be performed through a
secure VPN connection. This may, however, entail security
risks and thus requires advanced computer skills.
The connection is made possible through the built-in OpenVPN
server (2). To do this, the data of the port or a DynDNS must be
entered on the page “Settings” (1). From this, a configuration
file will be created which is then loaded onto the device, and
imported into the OpenVPN program.
Afterwards, the incoming UDP traffic will be forwarded in the
router to port 1194 of the SmartController 7000.
An example of such a VPN connection will be shown in a
video which is available on our website www.tunze.com in the
article SmartController 7000 (7000.000).