TMI8 V2.1 

 

Subject to technical alterations 

Page -7- 

06/03/2018

 

 

TÜNKERS

®

 

Maschinenbau GmbH  Am Rosenkothen 8 • D-40880 Ratingen  Tel.  02102 4517-0 • Fax 02102 445808  Internet  www.tuenkers.de 

 

4.7  Housing and mechanics 
 

Material   

DIN EN 1706 EN AC-AlSi 12 

Protection category IP 66 in accordance with EN 60529 
Dimensions  

160 x 360 x 91 mm ( WxLxH) 

 
 

5.  Function 

 
After switching on the supply voltage of the device, the display of the 
current version number of the device-specific software appears as start 
message of the device. 
 
 
Start display

  => after 2 sec 

 
 
=> after 2 sec change into the normal operating display 
 
In the example here, software version V3.21 is displayed. 
 
After the start message, you change to the Automatic mode automati-
cally. 
 

5.1  Automatic 

 
Control of the 8 clamp is carried out via the respective 
fieldbus interface. The status message is carried out via the 
display. 
 
With the simultaneous control of several clamps, switching on of the 
individual clamps is time delayed (e.g. 10 ms). This limits the loading of 
the power supply due to the inrush current of the individual electric 
motors. 
 
If a KEBA terminal has to be connected, the status display does not 
change initially. The status is also visualised on the KEBA terminal. As 
soon as the menu selection or a respective sub-menu is se-
lected on the KEBA terminal, the operating mode and the 
display change to manual mode 
 
With the status display or when the KEBA terminal has been discon-
nected, the operating mode and the display change back into automatic 
mode. 
 
If errors occur, the status message changes to "Automatic mode with 
errors".

 

 

 
 
=>

 

after 2 sec 

 

after 2 sec  

 
 
 
Errors at clamp channel 5 and 6 are displayed as an example here. 
 

5.1.1  Data transmission Profinet IO / Ethernet-IP / Profibus-DP 
 

  DeviceNet 

 
Input data  

 

 

Commands 

 
Byte 1 

 

 

 

1.1 Clamping 1 closing 

 

 

 

 

1.2 Clamping 1 opening 

 

 

 

 

1.3 Clamping 2 closing 

 

 

 

 

1.4 Clamping 2 opening 

 

 

 

 

1.5 Clamping 3 closing 

 

 

 

 

1.6 Clamping 3 opening 

 

 

 

 

1.7 Clamping 4 closing 

 

 

 

 

1.8 Clamping 4 opening 

 
 
Byte 2 

 

 

 

2.1 Clamping 5 closing 

 

 

 

 

2.2 Clamping 5 opening 

 

 

 

 

2.3 Clamping 6 closing 

 

 

 

 

2.4 Clamping 6 opening 

 

 

 

 

2.5 Clamping 7 closing 

 

 

 

 

2.6 Clamping 7 opening 

 

 

 

 

2.7 Clamping 8 closing 

 

 

 

 

2.8 Clamping 8 opening 

 
 
Byte 3

   

 

 

3.1 Clamping error 1 rest 

 

 

 

 

3.2 Clamping error 2 rest 

 

 

 

 

3.3 Clamping error 3 rest 

 

 

 

 

3.4 Clamping error 4 rest 

 

 

 

 

3.5 Clamping error 5 rest 

 

 

 

 

3.6 Clamping error 6 rest 

 

 

 

 

3.7 Clamping error 7 rest 

 

 

 

 

3.8 Clamping error 8 rest 

 
 
Byte 4 

 

 

 

4.1 No function 

 

 

 

 

4.2 No function 

 

 

 

 

4.3 No function 

 

 

 

 

4.4 No function 

 

 

 

 

4.5 No function 

 

 

 

 

4.6 No function 

 

 

 

 

4.7 No function 

 

 

 

 

4.8 No function 

 

S3 

21 

AA 

HH 

AF 

51 

62 

8  7  6  5  4  3  2  1 

8  7  6  5  4  3  2  1 

8  7  6  5  4  3  2  1 

8  7  6  5  4  3  2  1 

Содержание TMI8 V2.1

Страница 1: ...ing maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 1 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Int...

Страница 2: ...tions and standards 3 3 Description of the safety function 3 4 Structure of the hardware 4 4 1 2 digit 7 segment display 4 4 2 Display LEDs for the fieldbus module 4 4 3 Display LEDs for electric clam...

Страница 3: ...put Fieldbus device variant DeviceNet PROFIBUS DP PROFINET IO or Ethernet IP 8 outputs Clamping motors 1 output Hand held terminal The control is galvanically isolated from the supply 2 Operating cond...

Страница 4: ...Defective motor driver 14 Initiator error Close Open 16 Deactivation via adjustable current limit values 21 86 Error codes clamp channel 2 8 4 2 Display LEDs for the fieldbus module Green LED B1 B2 B...

Страница 5: ...connector input 24V voltage supply control voltage IO Bus and int logic XS2 M12 circular connector 4 pin connector output 24V voltage supply control voltage IO Bus and int logic XS3 M23 circular conne...

Страница 6: ...re can be established by both connectors The device TMI 8 PB is equipped with a Profibus interface XBA Output Profibus interface M12 socket 5 pin B coding XBE Input Profibus interface M12 connector 5...

Страница 7: ...change initially The status is also visualised on the KEBA terminal As soon as the menu selection or a respective sub menu is se lected on the KEBA terminal the operating mode and the display change t...

Страница 8: ...load voltage present 1 Byte 6 8 Reserve 5 1 2 Control program In EB 1 or EB2 the fieldbus master can either trigger an Open com mand or Close command for the respective clamp If the clamp is position...

Страница 9: ...of the TMI8 in automatic mode is displayed If the menu selection is selected in the KEBA terminal the TMI8 changes to manual mode When returning to the status display on the KEBA terminal the TMI8 is...

Страница 10: ...sulation between control voltage Ust and load voltage UI Insulation voltage min 3750V rpm UL certification in accordance with UL1577 VDE certification in accordance with VDE V 0884 5 10 or EN60747 5 2...

Страница 11: ...r EMC base standard Test value Housing Discharging of static electricity ESD Electromagnetic fields Power frequency magnetic fields IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 8 4kV contact discharge 8kV...

Страница 12: ...maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 12 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Intern...

Отзывы: