background image

Tünkers 8-Channel Motor Terminal 

for controlling maximum 8 electronic clamping devices

 

TMI8 V2.1 

 

Subject to technical alterations 

Page -10- 

06/03/2018

 

 

TÜNKERS

®

 

Maschinenbau GmbH  Am Rosenkothen 8 • D-40880 Ratingen  Tel.  02102 4517-0 • Fax 02102 445808  Internet  www.tuenkers.de 

 

6.  Electrical characteristics 

 

Input / output control voltage Ust at XS1/XS2: 

Voltage SELV or PELV in accordance with EN 61010-2-201

 

 
Uin 

+24V 

+/- 10% 

Residual ripple 1.2 V 

 

No-load: 

Iin 

0.05A

typ

  

0.075A

max 

no connection  

 

 

 

Initiators / motors /  

 

 

 

general inputs 

Iin 

0.035A

typ

  

0.05A

max 

per line pair initiator / motor 

Iin 

0.05A

 typ

 

0.1A

max 

per general input  

 

 

 

(depending on the initiator) 

Iin

no-load

  0.25A

 type 

0.575A

max 

No-load with 6 connected  

 

 

 

 

initiators and clamps and  

 

 

 

 

4 general inputs. 

Full load: 

Iin 

0,5 A

type

  

1,2 A

max

 

 
 

Input load voltage Ul at XS3: 

 
Uin 

+24V 

+/- 10% 

Residual ripple 1.2 V 

Iin

no-load

  0,1A

type

  

0,15A

max

  

no control of the  

 

 

 

clamping motors 

 

55A

peak

/5ms 

Inrush peak current  

 

 

(Load int. capacitors) 

 

50A

peak

/5ms 

Switch on after 5 sec  

 

 

Power failure 

 

40A

peak

/5ms 

Switch on after 4 sec  

 

 

Power failure 

 

30A

peak

/5ms 

Switch on after 5 sec  

 

 

Power failure 

 

20A

peak

/5ms 

Switch on after 2 sec  

 

 

Power failure 

 

10A

peak

/5ms 

Switch on after 1 sec  

 

 

Power failure 

 
Iin 

4A

Time

  

with the active command execution per   

 

 

clamping drive (EK63) 

 

25A

peak 

Inrush current of the clamp motor (EK63) 

 
 

With control of 6 clamps at the same time: 

 

24A

Time 

/ 35A

peak

 (specification for power supply) 

 

Insulation between control voltage Ust and load voltage UI 

 
Insulation voltage   

min 

3750V (rpm) 

 
UL certification in accordance with UL1577 
VDE certification in accordance with VDE V 0884-5/-10 or EN60747-5-
2/-5 
 

Motor signals to XA1 

– XA8  

 
Iout 

4A  

 

for a max. movement time of 5s 

 

25Apeak   

5ms/50ms (ta/tf) 

 
Internal temperature and short-circuit monitoring of the motor driver 

Connection initiators for end position detection XE1 

– XE8  

(Plus switching) 

 
Uout 

+/-24V 

+/- 10% 

Residual ripple 1.2 V 

Iout 

50mA

Time 

100mA

peak

 

Iin 

5mA 

+/- 10% 

Plus pole switched 

 

Connection general inputs XE9 

– XE12 (Plus switching) 

 
Uout 

+/-24V 

+/- 10% 

Residual ripple 1.2 V 

Iout 

100mA

Time 

150mA

peak

 

Iin 

5mA 

+/- 10% 

Plus pole switched 

 

Interface PROFINET-IO XBA and XBE (TMI-8 PN)  

 
Baud rate:  

100 MBaud 

Ethernet protocol 

UDP/IP, TCP/IP 

 

Interface Ethernet-IP XBA and XBE (TMI-8 EIP)  
 

Baud rate 

10 and 100MBit/s autodetect

 

Ethernet IP/Address 

Assignment via DHCP server 

Ethernet protocol 

UDP/IP or TCP/IP 

 

Integrated web server- there is one HTML screen on which the system 
parameters of the Ethernet IP module are represented. The web screen 
can be edited or replaced by a customer-specific web screen. 
 
Integrated FTP server that permits access to the data system of the 
device via the field bus. Access is protected by user names and pass-
word. 
 

Interface DeviceNet XBA and XBE (TMI-8 DN) 

 
Data rate  

125KBit (default setting), 250kBit, 500KBit  

Data format 

Group 2 Slave 

Vendor ID 

272 

Device type 

12 (communication adapter) 

 

Interface Profibus XBA and XBE (TMI-8 PB) 

 
Data rate  

500KBit (default setting), 1.5 MBit  

Diagnosis data: 

max. 8 Byte 

Sync: 

supported

 

Freeze: 

supported 

ID-No.: 

0x2079 or 0x3218 

 

Содержание TMI8 V2.1

Страница 1: ...ing maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 1 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Int...

Страница 2: ...tions and standards 3 3 Description of the safety function 3 4 Structure of the hardware 4 4 1 2 digit 7 segment display 4 4 2 Display LEDs for the fieldbus module 4 4 3 Display LEDs for electric clam...

Страница 3: ...put Fieldbus device variant DeviceNet PROFIBUS DP PROFINET IO or Ethernet IP 8 outputs Clamping motors 1 output Hand held terminal The control is galvanically isolated from the supply 2 Operating cond...

Страница 4: ...Defective motor driver 14 Initiator error Close Open 16 Deactivation via adjustable current limit values 21 86 Error codes clamp channel 2 8 4 2 Display LEDs for the fieldbus module Green LED B1 B2 B...

Страница 5: ...connector input 24V voltage supply control voltage IO Bus and int logic XS2 M12 circular connector 4 pin connector output 24V voltage supply control voltage IO Bus and int logic XS3 M23 circular conne...

Страница 6: ...re can be established by both connectors The device TMI 8 PB is equipped with a Profibus interface XBA Output Profibus interface M12 socket 5 pin B coding XBE Input Profibus interface M12 connector 5...

Страница 7: ...change initially The status is also visualised on the KEBA terminal As soon as the menu selection or a respective sub menu is se lected on the KEBA terminal the operating mode and the display change t...

Страница 8: ...load voltage present 1 Byte 6 8 Reserve 5 1 2 Control program In EB 1 or EB2 the fieldbus master can either trigger an Open com mand or Close command for the respective clamp If the clamp is position...

Страница 9: ...of the TMI8 in automatic mode is displayed If the menu selection is selected in the KEBA terminal the TMI8 changes to manual mode When returning to the status display on the KEBA terminal the TMI8 is...

Страница 10: ...sulation between control voltage Ust and load voltage UI Insulation voltage min 3750V rpm UL certification in accordance with UL1577 VDE certification in accordance with VDE V 0884 5 10 or EN60747 5 2...

Страница 11: ...r EMC base standard Test value Housing Discharging of static electricity ESD Electromagnetic fields Power frequency magnetic fields IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 8 4kV contact discharge 8kV...

Страница 12: ...maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 12 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Intern...

Отзывы: