6. Electrical characteristics
Input / output control voltage Ust at XS1/XS2:
Voltage SELV or PELV in accordance with EN 61010-2-201
Uin
+24V
+/- 10%
Residual ripple 1.2 V
No-load:
Iin
0.05A
typ
0.075A
max
no connection
Initiators / motors /
general inputs
Iin
0.035A
typ
0.05A
max
per line pair initiator / motor
Iin
0.05A
typ
0.1A
max
per general input
(depending on the initiator)
Iin
no-load
0.25A
type
0.575A
max
No-load with 6 connected
initiators and clamps and
4 general inputs.
Full load:
Iin
0,5 A
type
1,2 A
max
Input load voltage Ul at XS3:
Uin
+24V
+/- 10%
Residual ripple 1.2 V
Iin
no-load
0,1A
type
0,15A
max
no control of the
clamping motors
55A
peak
/5ms
Inrush peak current
(Load int. capacitors)
50A
peak
/5ms
Switch on after 5 sec
Power failure
40A
peak
/5ms
Switch on after 4 sec
Power failure
30A
peak
/5ms
Switch on after 5 sec
Power failure
20A
peak
/5ms
Switch on after 2 sec
Power failure
10A
peak
/5ms
Switch on after 1 sec
Power failure
Iin
4A
Time
with the active command execution per
clamping drive (EK63)
25A
peak
Inrush current of the clamp motor (EK63)
With control of 6 clamps at the same time:
24A
Time
/ 35A
peak
(specification for power supply)
Insulation between control voltage Ust and load voltage UI
Insulation voltage
min
3750V (rpm)
UL certification in accordance with UL1577
VDE certification in accordance with VDE V 0884-5/-10 or EN60747-5-
2/-5
Motor signals to XA1
– XA8
Iout
4A
for a max. movement time of 5s
25Apeak
5ms/50ms (ta/tf)
Internal temperature and short-circuit monitoring of the motor driver
Connection initiators for end position detection XE1
– XE8
(Plus switching)
Uout
+/-24V
+/- 10%
Residual ripple 1.2 V
Iout
50mA
Time
100mA
peak
Iin
5mA
+/- 10%
Plus pole switched
Connection general inputs XE9
– XE12 (Plus switching)
Uout
+/-24V
+/- 10%
Residual ripple 1.2 V
Iout
100mA
Time
150mA
peak
Iin
5mA
+/- 10%
Plus pole switched
Interface PROFINET-IO XBA and XBE (TMI-8 PN)
Baud rate:
100 MBaud
Ethernet protocol
UDP/IP, TCP/IP
Interface Ethernet-IP XBA and XBE (TMI-8 EIP)
Baud rate
10 and 100MBit/s autodetect
Ethernet IP/Address
Assignment via DHCP server
Ethernet protocol
UDP/IP or TCP/IP
Integrated web server- there is one HTML screen on which the system
parameters of the Ethernet IP module are represented. The web screen
can be edited or replaced by a customer-specific web screen.
Integrated FTP server that permits access to the data system of the
device via the field bus. Access is protected by user names and pass-
word.
Interface DeviceNet XBA and XBE (TMI-8 DN)
Data rate
125KBit (default setting), 250kBit, 500KBit
Data format
Group 2 Slave
Vendor ID
272
Device type
12 (communication adapter)
Interface Profibus XBA and XBE (TMI-8 PB)
Data rate
500KBit (default setting), 1.5 MBit
Diagnosis data:
max. 8 Byte
Sync:
supported
Freeze:
supported
ID-No.:
0x2079 or 0x3218