Tünkers 8-Channel Motor Terminal
for controlling maximum 8 electronic clamping devices
TMI8 V2.1
Subject to technical alterations
Page -4-
06/03/2018
TÜNKERS
®
Maschinenbau GmbH Am Rosenkothen 8 • D-40880 Ratingen Tel. 02102 4517-0 • Fax 02102 445808 Internet www.tuenkers.de
4. Structure of the hardware
4.1 2-digit 7-segment display
Status display:
AA
Automatic mode without error
HH
Manual mode if the had-held terminal is attached and the
function has been selected via the menu
AF
Automatic mode with errors -> alternating display
with error code
AF
Manual mode with errors -> alternating display
with error code
LS
Manual mode with errors -> alternating display
with error code
FF
Manual mode with errors -> alternating display
with error code
11
–
19
Error codes clamp channel 1
11
Error, the clamp remains stationary in the start po-
sition
12
3 sec timeout after initiating the command
13
Defective motor driver
14
Initiator error Close / Open
16
Deactivation via adjustable current limit values
21
–
86
Error codes clamp channel 2 - 8
4.2 Display LEDs for the fieldbus module
Green LED B1, B2, B3 and red LED B4 for displaying the fieldbus
status (XBA / XBE)
DeviceNet:
B1 - Internal voltage supply 3.3 V On or Off
B2 - Flashes if Bus is OK ... but has not yet
started
Continuous illumination when the bus has been
started correctly
B3 - no function
B4 - no function
Profibus:
B1 - Internal voltage supply 3.3 V On or Off
B2 - Continuous illumination when the bus has not been
started yet. Goes out when the bus is in the
data exchange mode
B3 - no function
B4 - no function
ProfiNet/
B1 - Flashes when a functional Ethernet is connected to
an XBA
Ethernet-IP: B2 - Off the bus has not started yet
Flashes 10 Hz error (ProfiNet only)
Flashes 2 Hz Bus started and waits for connection
(combination)
Illuminates when the connection has been estab-
lished
B3 - Flashes when a functional Ethernet is connected to
an XBE
B4 - Off, no error
Flashes ProfiNet participants flash test
Illuminates in case of bus error