ID551PN
Weighing Controller
7
[1.7.3]
Number of working load cells
Input the number of working load cells in this scale
[1.7.4 ]
Load Cell Sensitivity
Input the sensitivity of load cell, in general, It is 2mV/V or 3mV/V
[1.7.5 ]
Sensitivity calibration
A test weight is loaded to calibrate the sensor sensitivity, and the method reference End Point
[1.8 ] Filter
0
(
lowest
)
,
1
,
2
,
3
,
4
,
5
,
……18
,
19(
Highest
)
[1.9 ] Pushbutton Zero Range
0
–
Disable Pushbutton Zero
2
,
5
,
10
,
20
,
30
,
40
,
50
:
zero scale range is 2%
,
5%
,
10%
,
20%
,
30%
,
40%
,
50% of capacity
[1.10 ] Motion Check
[1.A ]
[1.A.1 ] :
View zero adjustment ADC code
[1.A.2 ] :
View span adjustment ADC code
[1.A.3 ] :
View span adjustment weight value
[1.A.4 ] :
Change or Enter zero adjustment ADC code
[1.A.5 ] :
Change or Enter span adjustment ADC code
[1.A.6 ] :
Change or Enter zero adjustment weight value
[3.0d]
0
–
Disable motion check
0.1~9.9 –
Enable motion check
[1.11 ] Auto Zero Range
0
–
Disable Auto Zero
0.1~9.9 -
0.1d - 9.9d, Enable
When set to >0, the auto zero tracking is within
±
10d
[1.12 ] Auto Zero Speed
0
–
Disable Auto Zero
0.1~9.9 -
Enable Auto Zero, Speed is
(0.1~9.9)d/second
[1.13 ] Tare
0
– Disable Tare
1
–
Enable Tare
[1.14 ] Application Mode
0
– Weight mode
1
–
Dynamometry mode