ID551PN
Weighing Controller
13
0-nonE
–
None
1-rtu1
3-cnt
Continuous Output Weight
/support command C
、
T
、
Z
4-Acnt Continuous output filter code
[6.5 ] COM Type
MODBUS-RTU1 Communication format
2-rtu2
MODBUS-RTU2
Communication format
0 – RS232
1 – RS485
[ 6.6 ] Modbus RTU Floating Format decoding order
0-3412
2.3.6 Network Configuration
,
word swap
1-1234
,
normal order
[ F 9.1 ] IP Address
Default:
192.168.18.1
as below configured
[9.1.1 ] : 192 [9.1.2 ]: 168 [9.1.3 ]: 1 [9.1.4 ]: 10
[ F 9.2 ] Submask
Default:
255.255.255.255
as below configured
[9.2.1 ] : 255 [9.2.2 ]: 255 [9.2.3 ]: 255 [9.2.4 ]: 0
[ F 9.3 ] Gateway
Default:
192.168.0.1
as below configured
[9.3.1 ] : 192 [9.3.2 ]: 168 [9.3.3 ]: 1 [9.3.4 ]: 1
[ F 9.4 ] LAN
0
– Disable
1 – TCP 1025
port continuous output
2 – TCP 1025
port continuous output
,
support command C
、
T
、
Z
[ F 9.5 ] M ODBUS-TCP
0
–Disable
1
– MODBUS-TCP1
2
– MODBUS-TCP2
[ F 9.5.1 ] Modbus TCP Floating Format decoding order
0-3412
,
word swap
1-1234
,
normal order
[9.6 ] TCP/UDP Continue output frequence
Default : 20
,
Range: 1 -100
,
if set to 100
,
100 times output per second.