WWW.TUCKERAUTO-MATION.COM
INSTALLATION
GUIDE
KP
evo
- TAP CONTROLLER
920.1003.02 | 15
2.4
S
G
N
I
N
R
A
W
Alerts provide information regarding the status or
current phase of the automation and errors that do
not prevent it from operating. It is possible to check
any current alerts via the KP EVO.
Go to menu 4 to view the list of current alerts.
If there is at least one alert, an icon appears on the
home screen.
F
s
g
n
i
n
r
a
W
41
Date and time missing
- Reset date/time via the KP EVO
42
Clock battery discharged or missing
44
Emergency
active (including command memory)
45
Timer active
46
Timer
function in progress
48
Night
mode operation
49
Manual
mode operation
50
Partial
mode operation
51
Obstacle detected during closure
52
Obstacle detected during opening
53
Number of maintenance cycles on E
2
prom corrupted
- Carry out a
Reset
.
- If the alarm persists, replace the
Logic
board
58
Searching for strike on closing
60
Maintenance requested
61
KP EVO fault
- Check that the correct device is connected and check the
connections.
- If the alarm persists, update the firmware
- If the alarm persists, replace the
Logic
board
63
Intrusion in progress
65
Set-up in progress
68
TEST
alarm (only if the “
test error
” parameter is enabled)
- Check the operation of the connected devices
- If the alarm persists, replace the device
- If the alarm persists, replace the
Logic
board
In this condition, the door moves at a slower speed.
69
Door opened by a semi-automatic command
71
Slave
Intercom
mode
72
Intercom
alarm
- Check the connections
- Check the
ID
- If the alarm persists, replace the
Logic
board
73
Slave
Error / Alarm
74
Interlock
alarm
- Check the connections
- Check the
ID
- If the alarm persists, replace the
Logic
board
80
Non-standard programming