WWW.TUCKERAUTO-MATION.COM
INSTALLATION
GUIDE
KP
evo
- TAP CONTROLLER
920.1003.02 | 16
2.5
S
R
O
R
R
E
Errors are malfunctions that prevent the automation
system from working. They are indicated by a steady
red LED on the
Logic
board.
After every 5 minutes in which a fault condition
persists and for a maximum of 20 consecutive times,
the 950N2 will perform a
Reset
to attempt to restore
normal operation so as not to require any action if the
condition that caused the error was temporary. If
the fault persists, remove the cause in order to restore
G
s
r
o
r
r
E
normal operation.
The type of error can be identified via the KP EVO
The error code appears on the home page. Go to
menu 5; the display provides information regarding
the current error.
When an error occurs:
1. Check all the electrical connections
2. Carry out a
reset
.
3. If the problem persists, carry out the operations described in the table one at a time until the problem is
resolved.
d
e
ri
u
q
e
r
n
oi
tc
A
r
o
rr
E
01
Board failure
- Replace the
Logic
board
02
E2
prom failure
- Replace the
Logic
board
03
Motor driver failure
- Replace the
Logic
board
- Replace the motor
04
Accessories power supply fault
- Check that the accessories power supply is not short circuited
- Check that maximum load of the accessories has not been exceeded
- Replace the
Logic
board
- Replace the
I/O
board
05
Microcontroller error
- Reload/update the
Logic
board firmware
- Replace the
Logic
board
07
Motor failure
- Replace the motor
-
Replace the
Logic
board
09
Board voltage anomaly
-
Replace the
Logic
board
-
Replace the
I/O
board
11
Closing safety
TEST
failed
- Check the connections of the safety device
- Check that the safety device is working
-
Replace the
Logic
board
12
Opening safety
TEST
failed
- Check the connections of the safety device
- Check that the safety device is working
-
Replace the
Logic
board
15
Setup
inhibited
- Make sure that
Night
or
Manual
mode has not been set.
- Make sure that an
Emergency
command has not been activated
16
Encoder fault
-
Replace the
Logic
board
18
Firmware not compatible
- Update with the correct firmware
19
High mechanical friction
- Make sure that the leaf has been mounted correctly and that it moves smoothly,
remove any friction
- Replace the
Logic
board
- Replace the gearmotor
22
Programming data corrupted
- Reprogram the board or upload the program files that were saved to the USB
storage device.
- Replace the
Logic
board