INSTALLATION
GUIDE
KP
evo
- TAP CONTROLLER
920.1003.02 | 11
Emergency close with memory
When activated, the door closes and remains closed as long as the
input is active. When released, the door remains closed until it
is
Reset
Fire alarm
When activated, the door closes, regardless of the operating mode
that has been set, with the lock kept in the released position. It
has priority over any commands that may be active.
Always open
When activated, the
ALWAYS OPEN
mode is set.
Exit only
When activated, the
EXIT ONLY
mode is set.
Entry only
When activated, the
ONLY IN
operating mode is set.
Night
When activated, the
NIGHT
mode is set.
Manual
When activated, the
MANUAL
mode is set.
Partial
When activated, the
PARTIAL
mode is set.
Interblock ON
When activated, the
INTERLOCK
mode is set.
Timer
When activated, the
TIMER
mode is set.
OUTPUTS
The outputs on terminal board J5 of the
I/O
board can be configured
with the following functions
Each input can be set to NC or NO according to the
device connected to it.
Disabled
No associated function.
Gong
The output is activated and deactivated at 1-second intervals when
the safety devices are engaged.
Error
The output is activated if there is an error.
Emrg. active
The output is activated when an
Emergency
is triggered.
Test
The output commands a
FAILSAFE
test on the inputs that are config-
ured as safety devices on which the option of running a
TEST
before
movement has been enabled.
Door not closed
The output remains active until the door is closed.
Door open
The output remains active as long as the door is open.
Door opening
The output remains active as long as the door is moving.
Light
The output is activated, for
a programmable length of time, w
hen the
door is open in
NIGH
T mode.
Intrusion active
The output is activated when an intrusion is in progress (i.e. when an
unexpected movement of the door from its closed position is detected).
Closing safety
The output is activated when a closing safety device is active.
Safeties
The output is activated when a closing or opening safety device
is engaged.
OP/CL
RELAY
Specifies the
logic
of the door status relay (NC/NO).
EXTERNAL SELECTOR
Specifies the operating mode associated with positions 1 and 2 of
the selector on the side of the unit.
■
PROGRAMMING MOTION
OPENING/CLOSING
Speed
Sets the speed of movement.
Deceleration
Specifies the space (in degrees of rotation of the 950N2 shaft) and
the deceleration speed (on 3 levels) of the door before reaching the
final open / closed positions.
Strength
Specifies the maximum crushing force.
Strength duration
Specifies the maximum thrust time before an obstacle is recognised.
Acceleration
Specifies how quickly the door reaches the set opening speed when
starting from stop.
Deceleration
Specifies how quickly the door stops.
■
PROGRAMMING TIMING
PAUSE TIME
Defines the pause time of the door when opened by a command,
before closing automatically.
PAUSE TIME P&G
Sets the door pause time when opened by a
Push & Go
command,
before closing automatically.
Night PAUSE TIME
Sets the door pause time when opened by a command in
NIGHT
mode, before closing automatically.
NIGHT SENSOR DELAY
When
NIGHT
mode is set, the internal detector remains active for the
amount of time set in this parameter, to allow it to be opened only
once. The internal detector is disabled immediately after opening
and in any case upon expiry of the set delay.
■
PROGRAMMING MOTOR BLOCK KIT
FUNCTION
Specifies the operating mode in which the lock is activated.
LOCK DELAY
Specifies the opening delay time of the door to allow the lock to be
released, particularly motorised locks.
RELEASE TYPE
Specifies when power is disconnected from the lock after it has been
mechanically released:
Opening
= during the opening phase
Closed
= when the door is closed again