6.A Module Product Specification
C1 Product
Type of Modules (Series)
TS-110C1 TS-115C1 TS-120C1 TS-125C1 TS-130C1 TS-135C1 TS-140C1 TS-145C1 TS-150C1 TS-155C1 TS-160C1 TS-165C1
Maximum power (P
max
)
110
115
120
125
130
135
140
145
150
155
160
165
Open-circuit voltage (V
oc
)
62.0
62.3
62.6
63.0
63.3
63.6
63.9
64.2
64.5
64.8
65.2
65.5
Short-circuit current (I
sc
)
3.61
3.61
3.61
3.61
3.61
3.61
3.61
3.61
3.61
3.61
3.61
3.61
Maximum power voltage (V
mpp
)
35.6
37.0
38.2
39.7
41.0
42.3
43.6
44.9
46.0
47.4
48.8
50.0
Maximum power current (I
mpp
)
3.09
3.11
3.14
3.15
3.17
3.19
3.21
3.23
3.26
3.27
3.28
3.30
Module efficiency
10.1%
10.6%
11.0%
11.5%
12.0%
12.4%
12.9%
13.4%
13.8%
14.3%
14.7%
15.2%
Certified by
TUV SUD
Maximum system voltage (Vsys)
Maximum series fuse rating
Temperature coefficient of Pmax
Mechanical load
Dimension in inches (inch/mm)
Weight in lbs (kg)
Frame
38.5 (17.5)
Black Anodized Aluminum
TUV SUD
TUV SUD / UL
1000Vdc / 600Vdc(UL)
6A
-0.31%/
℃
2400Pa (IEC) / 1695Pa (35lb/ft2, UL)
25.8 (656) x 65.2 (1656) x 1.4 (35)
C1HV Product
Type of Modules (Series)
TS-130C1HV TS-135C1HV TS-140C1HV TS-145C1HV TS-150C1HV TS-150C1HV TS-160C1HV
Maximum power (P
max
)
130
135
140
145
150
155
160
Open-circuit voltage (V
oc
)
63.3
63.6
63.9
64.2
64.5
64.8
65.2
Short-circuit current (I
sc
)
3.61
3.61
3.61
3.61
3.61
3.61
3.61
Maximum power voltage (V
mpp
)
41.0
42.3
43.6
44.9
46.0
47.4
48.8
Maximum power current (I
mpp
)
3.17
3.19
3.21
3.23
3.26
3.27
3.28
Module efficiency
12.0%
12.4%
12.9%
13.4%
13.8%
14.3%
14.7%
Certified by
Maximum system voltage (Vsys)
Maximum series fuse rating
Temperature coefficient of Pmax
Mechanical load
Dimension in inches (inch/mm)
Weight in lbs (kg)
Frame
UL
1000Vdc(UL)
6A
-0.31%/
℃
1695Pa (35lb/ft2, UL)
25.8 (656) x 65.2 (1656) x 1.4 (35)
38.5 (17.5)
Black Anodized Aluminum
Measured at STC: Irradiance 1000W/m
2
and cell temperature 25°C (77°F) AM=1.5 after factory light soaking.
All r/- 10%, unless specified otherwise. Specifications are subject to change
Pmax Tolerance (UL) after IEC Light Soaking is +10%/-5%, before IEC Light Soaking Tolerance is +/-5%
Refer to datasheet for potential increases in Pmax, Voc and Vmpp after post-installation light soaking.
6.B Electrical Installation
“Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current
and/or voltage than reported at standard test conditions. The requirements of the National Electrical Code (NEC)
in Article 690 shall be followed to address these increased outputs. In installations not under the requirements of
the NEC, the values of I
SC
and V
OC
marked on this module should be multiplied by a factor of 1.25 when
determining component voltage ratings, conductor ampacities, overcurrent device ratings, and size of controls
connected to the PV output.”
The multiplying factor at conditions of an irradiance of 1250 w/m
2
, AM1.5 spectrum, and a cell temperature of
-10°C (+14°F) for Voc is 1.25 and at cell temperature of 75°C (167°F) for Isc it is 1.25.
For field connections, use approved PV Copper wire only, minimum No. 14 AWG (2.5mm
2
) wires insulated for
minimum of 90°C, rated for wet conditions and resist to ultra violet radiation (where exposed)
Содержание TS-110C1
Страница 14: ...Figure 12 Middle Clamp Figure 13 End Clamp...
Страница 15: ...Figure 14 Module Clamp Mounting Method...