Mechanical Components 

Mounting mechanical means to be used in clamp or bolt methods are as below and as shown in Table 1:·   

Screw/Bolt:   

M6 Stainless Steel 

Nut: 

 

 

M6 Stainless Steel Flange Nut 

Washer: 

 

M6 Stainless Flat Washer, M6 Spring Washer 

Torque Value: 

6.1 ~ 7 N-m [54.0~61.9 in-lb] 

Clamps: 

 

Aluminum 

 

50 [1.96"]

M6 NUT

M6 WASHER

TOP CLAMP

M6 FLANGE NUT

BOTTOM CLAMP

M6 BOLT (L: 55~65mm) [2.16"~2.56"]

MOUNTING STRUCTURE BEAM

60 [2.36"]

30 [1.18"]

50 [1.96"]

MIDDLE CLAMP

50 [1.96"]

M6 SPRING WASHER

 

 

Table 1 Mounting Method Mechanical Components       

 

 

 

 

All measurements in mm [inches] 

Содержание TS-110C1

Страница 1: ...al Version 2 4 12 1 2014 TS CIGS C1 Series TS 110C1 TS 115C1 TS 120C1 TS 125C1 TS 130C1 TS 135C1 TS 140C1 TS 145C1 TS 150C1 TS 155C1 TS 160C1 TS 165C1 TS 130C1HV TS 135C1HV TS 140C1HV TS 145C1HV TS 15...

Страница 2: ...0C2 and deleted Models TS 125C2 TS 130C2 TS 135C2 and TS 140C2 for UL certification 10 1 2013 2 1 Update product specification in section 6A and add new models TS 165C2 TS 170C2 and statements in Sect...

Страница 3: ...responsibility for any infringement of patents or other rights of third parties that may result from use of the modules unless we are automatically liable If you do not adhere to the instructions giv...

Страница 4: ...talling or troubleshooting photovoltaic systems Work only in dry conditions with dry modules and tools Do not install the module where flammable gases or vapors are present Never leave a module unsupp...

Страница 5: ...ctures that are to be used to support TSMC Solar modules must be wind rated and approved for use by the appropriate local and civil codes prior to installation In Canada the installation must be done...

Страница 6: ...14 7 Certified by Maximum system voltage Vsys Maximum series fuse rating Temperature coefficient of Pmax Mechanical load Dimension in inches inch mm Weight in lbs kg Frame UL 1000Vdc UL 6A 0 31 1695Pa...

Страница 7: ...ult in damage to the module Avoid immersion of cables and connectors in water and site them away from areas prone to water collection Ensure a minimum clearance of 10mm between the ground roof surface...

Страница 8: ...s used the modules are recommended to be mounted in portrait orientation short side parallel to ground for best performance If modules are mounted in landscape orientation long side parallel to ground...

Страница 9: ...4 mounting hole locations denoted M1 in Figure 6 This method enables a maximum mechanical loading of 2 400N m2 50PSF IEC too in a static state on the module surface The 4 mounting holes located furth...

Страница 10: ...odules are mounted on a permanent structure they should be tilted so that the energy production from the modules will be maximized on an annual basis Generally this result will be achieved when the ti...

Страница 11: ...ant with the latest regulations that are applicable for the jurisdiction where the system is installed e g the NEC National Electric Code in the United States If the building is already equipped with...

Страница 12: ...Certified by UL only In addition WEEB Washer Electrical Equipment Bond grounding parts with UL 467 listing can be used with TSMC Solar module The WEEB parts must be installed in accordance to the man...

Страница 13: ...ring rated for the application Clamp Method The module is secured to the mounting structure by clamping A clamping solution requires a top clamp piece that braces the front of the module frame and a r...

Страница 14: ...Figure 12 Middle Clamp Figure 13 End Clamp...

Страница 15: ...Figure 14 Module Clamp Mounting Method...

Страница 16: ...e 15 requires that the spring washer be first placed on the bolt followed by the insertion of the bolt first through the module mounting hole in the aluminum frame then through the system rail Finally...

Страница 17: ...eel Flange Nut Washer M6 Stainless Flat Washer M6 Spring Washer Torque Value 6 1 7 N m 54 0 61 9 in lb Clamps Aluminum 50 1 96 M6 NUT M6 WASHER TOP CLAMP M6 FLANGE NUT BOTTOM CLAMP M6 BOLT L 55 65mm 2...

Страница 18: ...st 2 digits of year e g 11 2011 12 2012 4 th Month 1 9 Jan Sep respectively A C Oct Dec respectively 5 th 6 th Day 01 31 2 digit day e g 15 15 th of month 7 th 11 th Internal Use Defined for TSMC Sola...

Отзывы: