are quite rugged, the glass may be broken if it is dropped or hit by tools or other objects and the module will
no longer work properly. The module must not be exposed to concentrated sunlight, e.g. sunlight focused by
mirrors, lenses or other magnifiers.
The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is placed
in a salt-water environment in contact with a rack made of another type of metal (Electrolytic Corrosion). If
required, stainless steel washers can be placed between the module frame and support structure to prevent
this type of corrosion.
Any module support structures that are to be used to support TSMC Solar modules must be wind rated and
approved for use by the appropriate local and civil codes prior to installation. In Canada, the installation
must be done in accordance with CSA C22.1, Safety Standard for Electrical installations, Canadian
Electrical Code, Part I.
Do not drill holes in the module frame
Any module without a frame (laminate) shall not be considered to comply with the requirements of UL 1703
unless the module is mounted with hardware that has been tested and evaluated with the module under this
standard or by a field Inspection certifying that the installed module complies with the requirements of UL
1703.
The module type has been qualified as
“Application Class A” under IEC 61730-1.