Figure 5 Clamp Zone
Bolt Method:
The frame of each module has 8 x 6.6 mm [0.26”] mounting holes. Modules mounted by bolting the frame to
mounting structure must use the 4 mounting hole locations denoted
“M1” in Figure 6. This method enables a
maximum mechanical loading of 2,400N/m2 (50PSF) (IEC) too, in a static state on the module surface.
The 4 mounting holes located further towards the short edge of the fr
ame than the “M1” holes are reserved for
future product use and may NOT be used with current products.
All measurements in mm [inches]