properly set. To obtain the current setting of the accuracy of the local time source, send
the string:
F36 A<CR>
3.38.25 The unit will respond with (example):
F36 A:1.0e-5<CR><LF>
This example illustrates a unit with an accuracy of 10 µs.
3.38.26 To set the accuracy of the NTS-100 module, send the string (example):
F36 A:0.5e-3<CR>
This example illustrates setting the accuracy of the NTS-100 module to 0.5 ms.
3.38.27 When the synchronization input option is GPS, the NTS-100 will automatically make this
setting, and operator attempts to set it will be ignored.
3.39
FUNCTION 66 - DAYLIGHT SAVINGS ENABLE
3.39.1
Use Serial I/O Function F66 to enable or disable or set the entry or exit times for DST.
The initial out-of-the-box default is "Off". The default upon subsequent power-ups will
be the selection in use just prior to the previous power-down.
3.39.2
To request the present status of the daylight savings enable, send F66<CR> to the serial
port. The port will respond with the ASCII character string:
F66<SEP><STATE><LT>
where
F
= ASCII character F.
66
= function number
<SEP>
= one or more separator characters: either space,
comma or tab.
<STATE>
= Off or Manual.
<LT>
= line terminator, either a carriage return and line feed
for output strings or a carriage return only for input
strings.