1/20/97
N
N
T
T
S
S
-
-
2
2
0
0
1
1
.
.
M
M
A
A
N
N
3
3
-
-
1
1
0
0
R
R
e
e
v
v
.
.
A
A
3.23
FUNCTION 18 - SOFTWARE VERSION REQUEST
3.23.1
Use keypad function 18 to obtain information about the current version of the software
installed in the unit.
3.23.2
Press "FUNC/ENTR", then "1" "8". The display will show, for example:
TRUETIME NTS-100
sys ver 002
3.23.3
Press any of the arrow keys, to change the display to the clock-specific version. For
example:
NTS v1.003
182-6007v001
3.23.4
Repeated presses of arrow keys will switch back and forth between the two displays.
3.23.5
The two examples shown indicate that the system software is version 14, and the clock-
specific software is version 1.011, PART NO. 182-6007v001.
3.23.6
To return to the status display, press the "FUNC/ENTR", or "STATUS" button.
3.24
FUNCTION 36 - NTS-100 CONFIGURATION ENTRY/REQUEST
3.24.1
Use function 36 to set the network parameters of the NTS-100 unit.
3.24.2
Press “FUNC/ENTR”, then “3” ”6”. The display will show:
Display Ethernet
Address
3.24.3
Use the up and down keys to scroll among the major selections for function 36: Display
Ethernet Address, Clock Type, Display/Setup Clock Accuracy, Display/Setup Network
Type, Display/Setup Default Gateway, Display/Setup Subnet Mask, Display/Setup IP
Address, and Display/Setup IRIG Lock Quality. Pressing "FUNC/ENTR" while the
desired action is displayed allows the user to view and/or modify the NTS-100
parameters. At any time a major selection is displayed, the Up and Down arrow keys
can be used to move to another major selection. This eliminates the need to view each
of the function 36 parameters if it is only desired to change one parameter.
3.24.4
Pressing "FUNC/ENTR" on “Display Ethernet Address” displays the Ethernet Address of
the unit as shown here:
Company:00-A0-69
(Fixed)
Unit:00-02-4F
(Example)
3.24.5
Press "FUNC/ENTR" to move onto the next parameter, or the “STATUS” button to exit
function 36 without saving any updated settings.
3.24.6
Pressing "FUNC/ENTR" on “Display/Setup IP Address” allows the user to view and/or
change the IP Address of the NTS-100 unit. The format of the IP Address display is
shown here:
IP Address:
255.054.000.034
(Example)
Содержание IRIG NTS-100