where
F
= ASCII character F.
01
= function number.
<SEP>
= one or more separator characters: either space,
comma or tab.
SIGN>
= either no character or + for positive offsets or - for
negative offsets.
<HH>
= one or two digit hours offset from +12 to -12 hours.
:
= ASCII character for a colon.
<MM>
= two-digit minutes offset.
<LT>
= line terminator, either a carriage return and line feed
for output strings or a carriage return only for input
strings.
Sample request:
F01<CR>
Response:
-4:30<CR><LF>
3.29.2
To set the time zone offset send a character string with the following format:
Sample entry:
F01 -8:00<CR>
Response:
OK<CR><LF>
Sample Request:
F01<CR>
Response:
-8:00<CR><LF>
3.30
FUNCTION 02 - 12/24 HOUR FORMAT ENTRY/REQUEST
3.30.1
Use Serial I/O function F02 to request or set the time display format. To determine the
format send F02<CR> to the Serial I/O port. The port will respond with the following
character string:
F02<SEP><HH><LT>
where
F
= ASCII character F.
02
= function number.
<SEP>
= one or more separator characters: either space,
comma or tab.
<HH>
= 12 or 24.
<LT>
= line terminator, either a carriage return and line feed
for output strings or a carriage return only for input
strings.
Sample request:
F02<CR>
Response:
F02 12<CR><LT>
3.30.2
To select 24 hour format, send the following character string:
Sample entry:
F02 24<CR>
Response:
OK<CR><LF>