............ www.truemfg.com ............
True Food Service Equipment, Inc.
8
8
INSTALLATION / OPERATION INSTRUCTIONS
Final Location
A.
Place styrofoam corners behind cooler for cushion
and carefully tilt unit on it’s back.
B.
Remove the louvered grill by removing four phillips-
head screws.
C.
Remove the four bolts from the skid with an
adjustable wrench, and locate the four castors.
Castors are placed inside cooler, within the bubble
wrap.
D.
Install one castor in each of the four female threaded
areas as indicated.
NOTE
Two out of the four castors are designated with an “F” for
front. These are provided with hand-brakes. Position these
castors in FRONT of the unit.
E.
When all castors have been threaded fully, replace
grill and lift unit; positioning it into its final location.
F.
Ensure that the two front castors are positioned
FORWARD as illustrated and locked down with the
hand-brakes.
WARNING
Unit may tip forward if procedure “F” is not
strictly followed.
G.
Units final location should be adequately ventilated.
Conditions where heat exceeds 100ºF require an
exhaust fan.
H.
Ensure that the drain hose for hoses are positioned in
the pan.
I.
Free plug and cord from inside the lower rear of the
cooler (Do Not Plug In.)
WARNING
Warranty is VOID if ventilation is insufficient.
J.
The unit should be placed close enough to the
electrical supply so that extension cords are NEVER
used.
WARNING
Cabinet warranties are void if OEM power cord is tampered
with. TRUE will not warranty any units that are connected to
an extension cord.
K.
Proper leveling of your TRUE cooler is critical to
operating success. Effective condensate removal and
door operation will be effected by leveling. Adjust
castors or add shims.
INSTALLING OPTIONAL CASTORS ON GDM-10
AND GDM-12 MODELS
POSITIONING OF THE
CASTOR IS CRITICAL.
ORIENT THE CASTOR IN
THE FORWARD POSITION
AS SHOWN