Model 3450
4–
TAKING MEASUREMENTS
NOTE
When not taking readings, always keep the source rod
in the SAFE (shielded) position. For added user safety,
the source rod automatically retracts to the SAFE
position when the gauge is lifted by the handle.
If you do not hear a
click
when the gauge is raised to the
SAFE
position, look at the bottom of the gauge to verify that the tungsten
sliding block is completely closed. If the gauge base opening is not
completely closed by the sliding block, the sliding block and fixed
tungsten block may require cleaning. Refer to page A–11 for
cleaning instructions.
The
Current Status
feature (see page 3–9) allows the operator to
view the current gauge status. This feature provides a quick
overview of all enabled functions (mode of operation, enabled
offsets, displayed units, etc.). Check the gauge’s current status
before taking measurements. To change any of the
Current Status
parameters, refer to Chapter 3.
Remember to take a standard count each day the gauge is to be used
(see page 4–2).
For more information on storing measured data, see the
If the gauge enters the sleep mode while taking counts, the red light
will flash more rapidly until the count is complete. To restore the
display, press any key.
WARNING
Do not store or transport the gauge unless the
sliding block is completely closed. Increased
radiation levels may cause excessive personnel
radiation exposure and may violate transportation
regulations.
4. U
SIN
G T
HE
G
AU
GE
Содержание RoadReader Plus 3450
Страница 7: ...Model 3450 vii NOTES...
Страница 13: ...xii NOTES...
Страница 17: ...1 4 GAUGE PARTS AND ACCESSORIES Figure 1 1 Model 3450 Parts and Accessories...
Страница 23: ...2 4 Figure 2 1 Effect of Moisture on Depth of Measurement...
Страница 53: ...3 28 NOTES...
Страница 169: ...Appendix E 2 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 171: ...Appendix E 4 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 173: ...Appendix E 6 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 175: ...Appendix E 8 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 181: ...Appendix G 4 NOTES...
Страница 187: ...Appendix H 6 NOTES...
Страница 199: ...Index 12 NOTES...
Страница 200: ...Model 3450 Warranty 1 NOTES WARRANTY...