3–24
If the
Thin Layer
mode is selected, the gauge prompts for the
overlay thickness. Use the number keys to enter the overlay
thickness, and press the
〈
ENTER
〉
key.
The gauge enables the selected measurement mode and returns to
the
Ready
display.
QA SAMPLING (SPECIAL KEY)
The
QA Sampling
function generates random sample locations.
Using random sample locations helps ensure fair and representative
quality assurance sampling. The gauge bases the QA sample
locations on the operator input for
average sample separation
and
total number of samples. The average sample separation is the
average distance between QA samples.
For example, if the QA protocol requires a sample every 500 feet on
a 2000-foot strip, the samples will be randomly separated and the
number of samples will be four. The first location will be a
randomly selected value between 1 and 500; the second between
501 and 1000; the third between 1001 and 1500; and the fourth
between 1501 and 2000.
After the gauge generates the sample locations, the operator can
view or print the locations as a guide for QA testing.
To access the
QA Sampling
menu, press the
〈
SPECIAL
〉
key. At the
Special
functions menu, access the
Special Operation
menu by
pressing
〈
1
〉
. At the
Special Operation
menu, press
〈
5
〉
QA Sampling
(use the arrow keys to scroll to choose
QA Sampling
). The gauge
displays the
QA Sampling
menu:
Use the corresponding number key to select a menu option.
QA Sampling
1- Set-Up Locations
2- View
3- Print
Press ESC to Exit
Содержание RoadReader Plus 3450
Страница 7: ...Model 3450 vii NOTES...
Страница 13: ...xii NOTES...
Страница 17: ...1 4 GAUGE PARTS AND ACCESSORIES Figure 1 1 Model 3450 Parts and Accessories...
Страница 23: ...2 4 Figure 2 1 Effect of Moisture on Depth of Measurement...
Страница 53: ...3 28 NOTES...
Страница 169: ...Appendix E 2 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 171: ...Appendix E 4 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 173: ...Appendix E 6 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 175: ...Appendix E 8 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 181: ...Appendix G 4 NOTES...
Страница 187: ...Appendix H 6 NOTES...
Страница 199: ...Index 12 NOTES...
Страница 200: ...Model 3450 Warranty 1 NOTES WARRANTY...