EN
6
Operating manual – convector TCH 20 E / TCH 22 E
Operation
Operating elements TCH 20 E
MIN
6
7
8
No.
Designation
6
flip switch heating levels 1250 W
(together with flip switch 7 = 2000 W)
7
flip switch heating levels 750 W
(together with flip switch 6 = 2000 W)
8
rotary switch room thermostat
Operating elements TCH 22 E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
MIN
6
7
8
9
10
13
11
12
No.
Designation
6
flip switch heating levels 1250 W
(together with flip switch 7 = 2000 W)
7
flip switch heating levels 750 W
(together with flip switch 6 = 2000 W)
8
rotary switch room thermostat
No.
Designation
9
timer
10
timer segments
11
timer indicator
12
timer control
13
flip switch turbo blowers
Switching the device on
1. Plug the device into a sufficiently fused socket.
2. Set the flip switch (6, 7) to
On
to select the desired heating
capacity.
You can actuate one flip switch for a capacity of 750 W (7)
or 1250 W (6), or both flip switches for the maximum
capacity of 2000 W.
ð
The lamp at the respective flip switch lights up.
3. When using the optional timer:
Set the timer control (12) to
I
.
Setting the room thermostat
1. Select the desired temperature via the stepless rotary
switch (8) of the room thermostat.
ð
If the room thermostat is switched on, the lamps of the
activated heating levels will light up.
The room thermostat controls the room temperature
automatically:
•
When the set value is exceeded, the heating switches off.
•
When the set value is fallen below, the heating
automatically switches back on.
Frost monitor function:
•
Turn the thermostat to the
*
marking (snowflake). In this
position, the room thermostat switches on the heating
automatically if the room temperature drops below the
frost protection temperature.
Switching on the turbo blowers (TCH 22 E only)
1. Set the flip switch for the fan (13) to
On
.
ð
The lamp at the flip switch lights up.
ð
The fan starts running if the room thermostat is
switched on.
ð
To distribute warm air, switch on the desired heating
level.
ð
At high room temperatures you can use the device to
distribute cold air. To do so, switch off the heating
levels.