background image

4

EN

Fog and flue gas simulator FS 200

Information about the device

Device description

The device serves the purpose of creating artificial fog by
means of fog fluid.
The fog fluid is sucked in by a pump and then heated. With the
integrated high-performance turbine and the thus producible
pressure the fog can be introduced both over long distances (e.
g. sewage pipes, large halls) and in installations with high
counter-pressure (e. g. flat-roofed constructions). Possible
application purposes are for example leak detection, fire brigade
training exercises, quality inspections, tightness tests etc.

Device depiction

7

6

3

1

2

5

4

2

3

No.

Designation

1

Transport handle

2

(Fold-up) canister holder

3

Air vent with filter

No.

Designation

4

Canister connection

5

Power cable

6

Fog transport hose connection

7

Control panel with protective flap

Control panel

8

9

10

11

12

13

14

15

1

No.

Designation

Meaning

8

On/off

 switch

For switching the device on
and off

9

Heating-up phase

 indicator Is illuminated when the

device heats up

10

Heating ready

 indicator

Is illuminated when the
device has heated up a is
ready for operation

11

Pump

 indicator

Is illuminated if the pump is
active and fog emerges

12

Magnetic lock for the
protective flap

Keeps the protective
flap (15) closed

13

Controller for the turbine

Controls the turbine speed

14

Controller for the pump

Controls the flow rate of the
pump

15

Protective flap

Protects the elements of
the control panel against
inadvertent adjustment

Содержание FS 200

Страница 1: ...TRT BA FS200 TC2014 24 004 EN FS 200 EN OPERATING MANUAL FOG AND FLUE GAS SIMULATOR ...

Страница 2: ... Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by ch...

Страница 3: ...bomb keep a safety distance of at least 3 m to the flue gas chamber Do not dispose of the spent smoke bomb until it has cooled down completely Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning The device is not a toy and does not belong in the hands of children Warning Dangers can occur at the device when it is used by untrained peop...

Страница 4: ...nation 1 Transport handle 2 Fold up canister holder 3 Air vent with filter No Designation 4 Canister connection 5 Power cable 6 Fog transport hose connection 7 Control panel with protective flap Control panel 8 9 10 11 12 13 14 15 1 No Designation Meaning 8 On off switch For switching the device on and off 9 Heating up phase indicator Is illuminated when the device heats up 10 Heating ready indica...

Страница 5: ... Device FS 200 1 x 5 m fog transport hose plastic DN 38 1 x connector with GEKA coupling 1 x 5 l of Fluitect fog fluid in canister 1 x Connecting hose fluid canister 1 x Quick guide Optional accessories Aluminium end connectors for poly flat roof Aluminium end connectors for flat bitumen roof Fluitect fog fluid 5 l in canister flue gas chamber and coloured smoke cartridges for fire simulation Tran...

Страница 6: ...d incombustible ground insensitive to heat vibration free minimum distance of 2 m to combustible or heat sensitive objects sufficient supply of fresh air Information regarding the operation with emergency power units The applied emergency power generators must be asynchronous feature a nominal capacity of min 4 kVA 230 V and be checked for proper functioning Before connecting the fog generator the...

Страница 7: ...eyed constantly roughly 12 o clock position 9 Use the turbine controller 13 to adjust the air volume as desired Info Keep in mind that the density of the fog depends on both the set pump capacity and the turbine performance Info If fog emerges from the ventilation grilles of the device the counter pressure at the outlet nozzle of the device is too high and the turbine power is set too low This cau...

Страница 8: ...t medium speed 3 Let the device run for approx 20 seconds with these settings to transport remaining fluids from the device 4 Actuate the on off switch 8 ð The green lamp goes off 5 Pull the mains plug Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device doe...

Страница 9: ...rting maintenance Do not touch the mains plug with wet or damp hands Before any work remove the mains plug Exchanging the canister A B C Cleaning filter mats Both filter mats must be cleaned on a regular basis In case of excessive contamination or damage the filter mats must be replaced A B C ...

Страница 10: ...ite the cleaning measures so called patina cannot always be prevented The function of the smoke box is not affected by this Cleaning Clean the device with a soft damp and lint free cloth Make sure that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners but only clean water to moisten the cloth Repair Do not modify the device or install ...

Страница 11: ...ctronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the en...

Страница 12: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: