8
EN
Fog and flue gas simulator FS 200
1. Connect the flue gas chamber to the fog transport hose
coming from the FS 200.
2. If required, connect another hose (Ø 38 mm) to the outlet
of the flue gas chamber.
3. Start the turbine of the device at low speed.
4. Open the cover of the flue gas chamber.
5. Put the smoke cartridge into the container.
6. Light the smoke cartridge at the very end of the fuse.
7. Then close the cover of the flue gas chamber again as
quickly as possible and lock it by use of the tension lock.
8. Set the desired turbine speed.
9. Set the corresponding pump capacity, if fog is to be added
to the coloured smoke.
Switching the device off
14
13
11
8
1. Use the controller (14) to switch the pump off again. The
pump
(11) indicator must no longer be illuminated.
2. Set the turbine controller (13) to
12 o'clock
position to let
the turbine run at medium speed.
3. Let the device run for approx. 20 seconds with these
settings to transport remaining fluids from the device.
4. Actuate the on/off switch (8).
ð
The green lamp goes off.
5. Pull the mains plug.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not generate any fog
•
Check, whether the device is ready for operation. The
heating ready
(10) indicator must be illuminated in green.
•
Check, whether the pump controller (14) is set to
8 o'clock
position. The
pump
(11) indicator should be illuminated in
blue.
•
Check, whether the device is switched on and connected
to the mains. The on/off switch (8) should be illuminated in
green.
•
Check the filling level of the canister. If required, exchange
the canister (see "Exchanging the canister").
•
Check all hoses and hose connections at the device for
tightness.
Your device still does not operate correctly after these
checks?
Please contact the Trotec customer service.