![Trolex Sentro 8 Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/trolex/sentro-8/sentro-8_user-manual_1171050096.webp)
96 TX9165-UM-EN-07
8.6 Battery Back-up Connections
If the Sentro 8 and battery back-up have
been purchased as a Sensor Station it will
be supplied mounted on a support and wired
together. No wiring between the Sentro 8,
battery back-up and any accessories will be
required.
It will be necessary to wire mains power into
the battery charger and data communications
into the battery back-up unit. System
drawings will be supplied by Trolex and
will indicate where power and data
communications need to be connected.
8.7 Operation
Operation of the Sentro 8 complete with
battery back-up is simple.
8.7.1 Power-up
1. At the start of each shift, open the
battery back-up housing. Check the
battery switch is in the
Off
position. If
the battery switch is in the
On
position
move it to the
Off
position.
2. Apply mains power to the Sentro 8 and
battery back-up in accordance with local
procedures.
3. With power applied move the battery
switch to the
On
position and close the
housing.