![Trolex Sentro 8 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/trolex/sentro-8/sentro-8_user-manual_1171050006.webp)
6 TX9165-UM-EN-07
1.2 Application
Fixed point multisensor environmental monitoring and machine condition
monitoring for use in underground mining and general purpose applications.
General Purpose
TX9165.03
Application:
Supply voltage:
Remote sensors:
Output relay contacts:
Non-hazardous areas
24 V dc
85 to 265 V ac supply
(universal)
24 V dc supply
2 Amps, 230 V ac
Underground Mining
and Tunnelling
TX9165.01i
Application:
Supply voltage:
Remote sensors:
Output relay contacts:
Type of protection:
Category:
ATEX:
Can be installed in
underground hazardous areas
12 V dc from an approved
source
Exi approved,12 V dc supply
Suitable for, and clearance
compatible for, switching other
intrinsically safe circuits
Intrinsically safe, EX ia
M1
94/9/EC
www.trolex.com