![Triumph Optimate 3 Plus Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/triumph/optimate-3-plus/optimate-3-plus_instructions-for-use-manual_1169785002.webp)
QUICK GUIDE – LED INFORMATION PANEL
Full details on any LED or step can be found in the manual under the same #
1. LED #1 - Power on. This LED confi rms AC power supply to the charger.
2. LED #2 indicates inverse polarity - wrong output connections. Swap around to activate output.
3. Circuit activation and recovery of deep-discharged, neglected batteries
3.1
ACTIVATION - If the battery voltage is above 2V, LED #3 lights briefl y to confi rm circuit activation.
For most batteries LED #3 goes out immediately and charge LED #4 comes on.
3.2
RECOVERY - For neglected or very fl at batteries, LED #3 remains on and indicates steadily.
If step 3 has not concluded after 2 hours, step 4 engages automatically.
4. Charge and charge verifi cation
4.1
CHARGE: A steady LED #4 indicates the bulk charge stage.
4.2
VERIFICATION: LED #4 fl ashes while the circuit verifi es battery charge level.
If the battery requires further charging the programme reverts to CHARGE. Multiple reversions may occur.
These reversions will cause LED #4 to alternate between steady and fl ashing, irregularly.
When LED #4 has fl ashed continuously for 30 minutes, step 5 engages and a voltage retention test starts.
5. 6. Voltage retention tests alternating half-hourly with battery maintenance
5.
For a good battery LED #5 fl ashes throughout the 30 minute test. NO CHARGE CURRENT.
6.
If the battery voltage falls below 12,4V during the test LED #6 (red) willcome on & indicate steadily.
Read § 6 in the main manual if LED #6 indicate in this period.
Maintenance - fl oat charge at a safe voltage limit to counter self-discharge.
Each test period is followed by a 30 minute maintenance charge period. Whichever LED (#5 fl ashing or #6 steady) was
indicating at the end of the TEST now indicates steadily. The battery can draw current as required to support small
loads & counter self-discharge.
Maintenance and voltage retention test periods continue alternating half-hourly until the battery is disconnected. The
test result is updated during each subsequent test.
LIMITED WARRANTY
Triumph Motorcycles Limited, Hinckley, Leicestershire LE10 3BS, England, makes this limited warranty to the original purchaser
at retail of this product. This limited warranty is not transferable. Triumph Motorcycles Limited warrants this battery charger
for two years from date of purchase at retail against defective material or workmanship. If such should occur the unit will
be repaired or replaced at the option of Triumph Motorcycles Limited. It is the obligation of the purchaser to forward the unit
together with proof of purchase, transportation or mailing costs prepaid, to the Triumph dealer from whom the unit was originally
purchased. This limited warranty is void if the product is misused, subjected to careless handling, or repaired by anyone other
than Triumph Motorcycles Limited’s authorized representative. Triumph Motorcycles Limited makes no warranty other than this
limited warranty and expressly excludes any implied warranty including any warranty for consequential damages.
THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND TRIUMPH MOTORCYCLES LIMITED NEITHER ASSUMES NOR
AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS
EXPRESS LIMITED WARRANTY. YOUR STATUTORY RIGHTS ARE NOT AFFECTED.
3
.1
3
.2
4
.1
4
.2
6
6
5
5
2
1
TEST MAINTAIN
CHARGE
VERIFY
DESULFATE
ACTIVATE
TM157-IN2-080701
TM157-IN2-080701.indd 1
22.03.10 16:28