3NL-2
1-3-25
U327
Setting the cassette heater control
Description
Sets the cassette heater control.
Purpose
To change the setting according to the machine installation environment.
Setting
1. Press the start key.
2. Select the item to set..
Initial setting: Off
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
Display
Description
Mode1
Setting On when the humidity is 65%. (when sleep mode and
waiting mode)
Mode2
Setting On in full-time. (when sleep mode and waiting mode)
Off
Cassette heater OFF