IVORY 4 electric shower

1

Products manufactured by Triton are safe and without risk provided they are installed, used and 

maintained in good working order in accordance with our instructions and recommendations.

WARNING:

 

DO NOT

 operate shower if frozen, or suspected of being frozen. It must thaw out 

before using.

DO NOT

 operate the unit if the showerhead or spray hose becomes damaged.

DO NOT

 restrict flow out of shower by placing showerhead in direct contact with your body.

DO NOT

 operate the shower if water ceases to flow during use or if water has entered inside 

the unit because of an incorrectly fitted cover.

WARNING:

 If restarting the shower immediately after stopping, be aware that a slug of 

hot water will be expelled for the first few seconds.

PLEASE READ THIS IMPORTANT SAFETY INFORMATION

GENERAL

1.1 

Isolate the electrical and water supplies before 

removing the cover.

1.2 

Read all of these instructions and retain them 

for later use.

1.3 

DO NOT

 take risks with plumbing or electrical 

equipment.

1.4 

Isolate electrical and water supplies before 

proceeding with the installation.

1.5 

The unit must be mounted onto the finished 

wall surface (on top of the tiles). 

DO NOT

 tile 

up to or seal around 

ANY PART

 of the unit 

using silicone sealer after fixing to the wall. 

Special care must be taken 

NOT TO BLOCK 

OR SEAL ANY PRD VENTS ON THE UNIT

.

1.6 

Contact Customer Service 

(see back page)

, if 

any of the following occur:

a) 

If it is intended to operate the shower at 

pressures above the maximum or below the 

minimum stated.

b) 

If the unit shows a distinct change in performance.

c) 

If the shower is frozen.

1.7 

If it is intended to operate the shower in areas 

of hard water (above 200 ppm temporary 

hardness), a scale inhibitor may have to be 

fitted. For advice on the Scale Inhibitor, 

contact Customer Service.

1.8 

The showerhead must be cleaned regularly 

with descalent to remove scale and debris, 

otherwise restrictions to the flow on the outlet 

of the unit will result in higher temperatures 

and could also cause the (PRD) Pressure Relief 

Device in the unit to operate.

1.9 

This product is not suitable for mounting into 

steam rooms or steam cubicles.

PLUMBING

2.1 

The plumbing installation must comply with 

Water Regulations, Building Regulations or any 

particular regulations as specified by Local 

Water Company or Water Undertakers and 

should be in accordance with BS EN 806.

2.2 

The supply pipe must be flushed to clear debris 

before connecting to the shower unit.

2.3 

DO NOT

 solder pipes or fittings within 300mm 

of the shower unit, as heat can transfer along 

the pipework and damage components.

2.4 

DO NOT

 fit any form of outlet flow control as 

the outlet acts as a vent for the heater can.

2.5 

DO NOT

 use excessive force when making 

connections to the flexible hose or 

showerhead, finger tight is sufficient.

2.6 

All plumbing connections must be completed 

before making the electrical connections.

2.7 

This appliance 

MUST 

not be connected to the 

inlet supply by a hose-set.

ELECTRICAL

3.1 

The installation must comply with BS 7671 

‘Requirements for electrical installations’ (IEE 

wiring regulations), building regulations or any 

particular regulations as specified by the local 

Electrical Supply Company.

3.2 

This appliance 

MUST 

be earthed.

3.3 

In accordance with ‘The Plugs and Sockets etc. 

(Safety) Regulations 1994’, this appliance is 

intended to be permanently connected to the 

fixed wiring of the electrical mains system.

3.4 

Make sure all electrical connections are tight to 

prevent overheating.

3.5 

A 30mA residual current device (RCD) 

MUST 

be installed in all UK electric and pumped 

shower circuits. This may be part of the 

consumer unit or a separate unit.

3.6 

Switch off immediately at isolating switch if 

water ceases to flow during use.

3.7 

Other electrical equipment i.e. extractor fans, 

pumps must not be connected to the circuits 

within the unit.

3.8 

Switch off at isolating switch when not in use. 

This is a safety procedure recommended with 

all electrical appliances.

3.9 

As with all electrical appliances it is 

recommended to have the shower and 

installation checked at least every two years by 

a competent electrician to ensure there is no 

deterioration due to age and usage.

Содержание IVORY 4

Страница 1: ...Installers please note these instructions are to be left with the user 2180775H April 2012 Installation and operating instructions IVORY 4 electric shower...

Страница 2: ...ing connections 11 Electrical connections 12 Replacing the cover 12 13 Commissioning 14 Operating the shower 15 16 Operating functions 17 Cleaning 17 Instructions for installers and service engineers...

Страница 3: ...and could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 PLUMBING 2 1 The plumbing installation mus...

Страница 4: ...rate at a constant rate at your chosen power setting It is the rate of the water passing through the heater can which determines the water temperature The slower the flow the hotter the water becomes...

Страница 5: ...ising valve 6 Solenoid valve 7 Can and element assembly 8 Thermal cut out TCO 9 Earth connection 10 Outlet pipe 11 Start Stop micro switch Pressure relief device see page 20 Cover fig 2 12 Ivory 4 fro...

Страница 6: ...bt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main sp...

Страница 7: ...dy while standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outl...

Страница 8: ...es per minute the inlet of the shower for full performance for 7 5Kw 8 5Kw 9 5Kw Minimum running pressure and flow to 150kPa 1 5 bar at 11 litres per minute the inlet of the shower for full performanc...

Страница 9: ...showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed...

Страница 10: ...t to remove them Lift the cover from the backplate Entry Points Water Left Bottom Back and Top Right Bottom Back Cable Left Bottom Back and Top The water inlet fig 7 has been designed to allow left or...

Страница 11: ...ide if top or bottom pipe entry is required Once chosen carefully remove the appropriate cut out using a junior hacksaw and file Please note NONE of the cut outs are designed as snap out entry points...

Страница 12: ...the backplate are shown in fig 10 Drill and plug the wall An appropriate drill bit should be used If the wall is brick plasterboard or a soft building block appropriate wall plugs and screws should b...

Страница 13: ...the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris...

Страница 14: ...ply cable must be secured either by rout ing through conduit or in trunking or by embed ding in the wall in accordance with current IEE regulations The use of connections within the unit to supply pow...

Страница 15: ...turn the stabi liser valve spindle fully clockwise until resistance is felt fig 14 4 With the cover off the shower turn the tem perature control so that it goes to Maximum HOT fig 16 c Make sure the...

Страница 16: ...he control to MINIMUM FLOW may cause the PRD to operate 2 Turn on the electric and mains water supplies to the shower 3 Turn the power selector to the COLD setting fig 18 and wait until water starts t...

Страница 17: ...ot be met due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit The symbol is a high power sett...

Страница 18: ...s advisable to be certain that the showering temperature is satisfactory by testing with your hand before stepping under the showerhead There will always be a time delay of a few seconds between selec...

Страница 19: ...will disconnect the heating elements It will require a visit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repaired TP Temperatur...

Страница 20: ...electricity supply and water supply at the mains The inlet filter is situated in the bottom of the inlet pipe fig 20 To gain access to the filter remove the cover and then unscrew the assembly from t...

Страница 21: ...ch Module P22611003 5 Can Assembly 8 5kW 83314800 Can Assembly 9 5kW 83314810 Can Assembly 10 5kW 83314820 6 Outlet Pipe and PRD S23511002 7 Terminal Block wires S82201240 8 Thermal Cut Out TCO 220123...

Страница 22: ...educe flow rate via temperature control Is water supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there...

Страница 23: ...4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 1 7 2 1 7 3 1 required see rating label Reduction in ambient water temperature Electrical malfunction or safety cut out operated Water pressu...

Страница 24: ...IVORY 4 electric shower 22 Entry Points Diagram Key Water Entry Points Cable Entry Points...

Страница 25: ...IVORY 4 electric shower 23...

Страница 26: ...IVORY 4 electric shower 24...

Страница 27: ...nt Agency under the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products a...

Страница 28: ...your details including post code the model number and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Se...

Отзывы: