TRI153.INS.046.3 - 08 March 2021
RTM - 75kW User Unit Installation Manual
www.tritium.com.au
Veefil®isaregisteredtrademarkofTritiumPtyLtd.©2021TritiumPtyLtd
Warning
Installation must not be made in a
commercial garage (repair facility) or
closer than 20 feet (6096 mm) of an
outdoor motor fuel dispensing device.
Input
400-480Vac 50-60 Hz (+/- 10%)
3 phase AC, no neutral
Nominal current at nominal voltage
level
Worldwide: 114A, US: 95A
Maximum current at low line lev-
el (Nominal voltage - 10% and
PF>0.99)
Worldwide: 114A, US: 105A
Recommended over-current protec-
tion device required (OCPD) in site
distribution board
Worldwide: 125A breaker, US: 125A
breaker
The RTM-75kW user unit must be
connected to a circuit provided with
appropriate over-current protection in
accordance with the national, regional
and local regulations in the country of
installation.
Tightening torque
Wiring and earth terminals
20Nm
Weather rating
IP65 Electronics Enclosure
Usage limitations
Cord extension sets or second cable
assemblies must not be used in
addition to the cable assembly for
the connection of the vehicle to the
charger.
Adaptors must not be used to
connect a vehicle connector to a
vehicle inlet.
Important safety instructions
SAVE THESE INSTRUCTIONS