11.0 Maintenance
11.1
Safety
Before starting any maintenance of the iGC:
Refer to the Section 4.2 - Safety Notes at the beginning of this manual.
All relevant parts of this section of the manual should be read and understood.
11.2
General
The iGC is designed for low maintenance operation using corrosion resistant materials, and generally
speaking does not require any preventative maintenance.
In addition there are no user serviceable parts inside the iGC.
11.3
Seals
Seal integrity is vital for the continued reliability of the iGC. There are two ‘O’-ring seals in the
assembly – one between the dome and end-cap and the other between the Subconn connector and
end-cap. The following should be noted:
Any time that a seal is disturbed, before replacement in the iGC it should be thoroughly cleaned
and inspected for damage.
The seal housing should be thoroughly cleaned and inspected for damage.
Any damaged seals or components with damaged sealing faces should be replaced with new
components.
All replacement seals should be correctly specified as per the iGC parts lists.
Never use ‘O’-rings made up by gluing cord to the correct length.
When replacing an ‘O’-ring, use an approved ‘O’-ring grease (such as Dow Corning 111
silicone compound) sparingly and make sure that all surfaces are kept clean during the process
of replacement.
The ‘O’-rings fitted to the iGC have a recommended service life of seven years.
Spare ‘O’-rings should be stored in suitable UV light proof bags or containers.
Issue 2
0707-SOM-00004
Page 32 of 51
Содержание Intelligent Gyro Compass
Страница 13: ...Tritech International Ltd Intelligent Gyro Compass Issue 2 0707 SOM 00004 Page 14 of 51 ...
Страница 30: ...Tritech International Ltd Intelligent Gyro Compass Typical screenshot Issue 2 0707 SOM 00004 Page 31 of 51 ...
Страница 43: ...Tritech International Ltd Intelligent Gyro Compass Appendix F Parts List Issue 2 0707 SOM 00004 Page 44 of 51 ...