TriStar MPPT Operator’s Manual

8

Important Safety Instructions

•  Servicing of batteries should be performed, or supervised, by personnel knowledgeable about    

batteries, and the proper safety precautions. 

•   Be very careful when working with large lead-acid batteries. Wear eye protection and have fresh 

water  available in case there is contact with the battery acid.

•  

Remove watches, rings, jewelry and other metal objects before working with batteries.

•  Wear rubber gloves and boots

 

 Use tools with insulated handles and avoid placing tools or metal objects on top of batteries.

•  Disconnect charging source prior to connecting or dis-connecting battery terminals.

•  Determine if battery is inadvertently grounded.  If so, remove the source of contact with ground.  

Contact with any part of a grounded battery can result in electrical shock.  The likelihood of such 
a shock can be reduced if battery grounds are removed during installation and maint enance    
(applicable to equipment and remote battery supplies not having a grounded supply circuit).

•  

Carefully read the battery manufacturer’s instructions before installing / connecting to, or removing 
batteries from, the TriStar MPPT.

•  

Be very careful not to short circuit the cables connected to the battery. 

•  

Have someone nearby to assist in case of an accident.

•  

Explosive battery gases can be present during charging. Be certain there is enough ventilation to 
release the gases.

•  

Never smoke in the battery area.

•   If battery acid comes into contact with the skin, wash with soap and water. If the acid contacts the 

eye, flood with fresh water and get medical attention.

•  

Be sure the battery electrolyte level is correct before starting charging. Do not attempt to charge a frozen 
battery. 

•  

Recycle the battery when it is replaced.

•  Entretien des batteries devrait être effectué ou supervisé, par un personnel bien informé sur les 

piles et les précautions de sécurité appropriées.

•  Soyez très prudent quand vous travaillez avec des grandes batteries au plomb. Portez des lunettes 

de protection et ayez de l’eau fraîche à disposition en cas de contact avec l’électrolyte.

•   Enlevez les montres, bagues, bijoux et autres objets mé talliques avant de travailler avec des piles.

•  Porter des bottes et des gants de caoutchouc 

•   Utiliser des outils avec poignées isolantes et évitez de placer des outils ou des objets métalliques 

sur le dessus de batteries.

•  Débrancher la source de charge avant de brancher ou dis-reliant les bornes de la batterie.

•  Utilisez des outils isolés et évitez de placer des objets métalliques dans la zone de travail.

• 

Déterminer si batterie repose par inadvertance. Dans l’affirmative, supprimer la source du contact 

avec le sol. Contact avec n’importe quelle partie d’une batterie mise à la terre peut entraîner un 
choc électrique. La probabilité d’un tel choc peut être réduite si des motifs de batterie sont suppri-
més pendant l’installation et maintentretien (applicable à l’équipement et les fournitures de pile de 
la télécommande n’ayant ne pas un circuit d’alimentation mise à la terre *).

•  Lisez attentivement les instructions du fabricant de la batterie avant d’installer / connexion à ou 

retrait des batteries du TriStar MPPT.

•  Veillez à ne pas court-circuiter les câbles connectés à la batterie.

•   Ayez une personne à proximité qui puisse aider en cas d’accident.

•  Des gaz explosifs de batterie peuvent être présents pendant la charge. Assurez-vous qu’une venti-

lation suffisante évacue les gaz.

•  Ne fumez jamais dans la zone des batteries

•  En cas de contact de l’électrolyte avec la peau, lavez avec du savon et de l’eau.  En cas de contact 

de l’électrolyte avec les yeux, rincez abondamment avec de l’eau fraîche et consultez un médecin.

•  Assurez-vous que le niveau d’électrolyte de la batterie est correct avant de commencer la charge. 

Ne tentez pas de charger une batterie gelée.

•  Recyclez la batterie quand elle est remplacée.

About this Manual

This manual provides detailed installation and usage instructions for the TriStar MPPT 150V  

controller. Only qualified electricians and technicians who are familiar with solar system design 

and wiring practices should install the TriStar MPPT 150V.  The usage information in this manual 
is intended for the system owner/operator. 

Содержание TS-MPPT-30

Страница 1: ...ng System Controller www morningstarcorp com Solar Battery Charger With TrakStarTM Maximum Power Point Tracking Technology MODELS TS MPPT 30 TS MPPT 45 TS MPPT 60 TRISTAR MPPT TM For the most recent m...

Страница 2: ...Controller Installation 18 4 0 Operation 34 4 1 TrakStarTM MPPT Technology 34 4 2 Battery Charging Information 36 4 3 Push button 43 4 4 LED Indications 44 4 5 Protections Faults Alarms 46 4 6 Inspect...

Страница 3: ...ht to avoid excessive heating from a loose connection Use properly sized conductors and circuit interrupters The grounding terminal is located in the wiring compartment and is identified by the symbol...

Страница 4: ...yst me et d application CAUTION Do not open or mutilate batteries Released electrolyte is harmful to skin and may be toxic PRUDENCE Ne pas ouvrir ou mutiler les piles L lectrolyte est nocif pour la pe...

Страница 5: ...unettes de protection et ayez de l eau fra che disposition en cas de contact avec l lectrolyte Enlevez les montres bagues bijoux et autres objets m talliques avant de travailler avec des piles Porter...

Страница 6: ...urement Please take the time to read this operator s manual and become familiar with the controller This will help you make full use of the many advantages the TriStar MPPT 150V can provide for your P...

Страница 7: ...2 29 battery chargers A means shall be provided to ensure all pole disconnection from the power supply This discon nection shall be incorporated in the fixed wiring Using the TriStar MPPT 150V ground...

Страница 8: ...enables the TriStar MPPT 150V to control external devices Four 4 relay control ports can be configured in various combinations to perform the following tasks generator control 2 3 and 4 wire configur...

Страница 9: ...ements are noted on occasion for convenience however the installer should have a complete understanding of NEC and UL requirements for photovoltaic installations Installation 3 0 Read through the enti...

Страница 10: ...through conduit or wire glands Table 3 1 below pro vides the knockout sizes and quantity on the TriStar MPPT 150V wiring box Knockout locations and dimensions are on the inside front cover Quantity T...

Страница 11: ...hole on the TriStar MPPT 150V with the screw head Slide the TriStar MPPT 150V down over the keyhole 7 Check for vertical plumb with a level 8 Mark two 2 mounting hole locations in the wiring box 9 Rem...

Страница 12: ...charges when the controller is con figured for automatic equalizations settings switch 7 Switch 7 Battery Equalization Choose between manual and automatic battery equalization charging In the manual...

Страница 13: ...RTS peut tre raccourci si la totalit de la longueur n est pas n cessaire Assurez vous de r installer la bobine en ferrite sur l extr mit du RTS si une longueur de c ble est enlev e Cette bobine assure...

Страница 14: ...rsed sense voltage Connecting the voltage sense wires to the RTS terminal will cause an alarm If a TriStar meter is installed check the TriStar Settings to confirm the Voltage Sense and the RTS if ins...

Страница 15: ...the connection of array terminals The battery positive terminal has a red cover the solar positive terminal has a yellow cover REMARQUE Pour la conformit CNE le TriStar MPPT 150V doit tre install sel...

Страница 16: ...des tensions de circuit ouvert sup rieures 150 Vdc la lumi re du soleil V rifiez que le coupe circuit ou l interrupteur d entr e solaire a t ouvert d connexion avant d installer les c bles du syst me...

Страница 17: ...TISSEMENT Risque d endommagement La connexion du r seau solaire sur la borne de la batterie endommagera le TriStar MPPT 150V de fa on permanente AVERTISSEMENT Risque d endommagement La connexion du r...

Страница 18: ...uit voltage Voc rating will not exceed the TriStar MPPT 150V 150 Volt maximum input voltage rating at worst case coldest module temperature The solar module documentation should provide Voc vs tempera...

Страница 19: ...the battery from long term overcharge The green SOC LED will blink once every two 2 seconds during Float charging Once in Float stage loads can continue to draw power from the battery In the event tha...

Страница 20: ...f the battery is fully recharged However a solar charged battery is seldom completely recharged so the soft lead sulfate crystals harden over a period of time Only a long controlled overcharge or equa...

Страница 21: ...ded to the normal Absorption duration Float Time out Figure 4 4 Float exit time out charging profile After entering Float stage the controller will only exit Float if the battery voltage remains below...

Страница 22: ...attery The controller will begin Absorption or limit equalization at a lower battery voltage because the controller measures a higher voltage at the controller s terminals than is the actual battery v...

Страница 23: ...R Battery service is required all three LEDs blinking until service is reset battery service notification is only enabled in custom settings or when any custom edit is programmed Battery Status Gener...

Страница 24: ...working properly Battery Voltage Sense Failure G R sequencing with constant yellow If a fault in the battery sense connection such as a short circuit open circuit or loose terminal occurs after the ba...

Страница 25: ...ce Battery Sense Out of Range Disconnected A battery sense wire is disconnected Inspect the battery sense connections This alarm is set when the voltage at the battery sense voltage differs by more th...

Страница 26: ...eously Table 5 1 below provides a summary of supported features for each communication interface MeterBus RS 232 EIA 485 Ethernet Display system network data on a TriStar meter Connect a TSMPPT to a R...

Страница 27: ...five 5 controllers can be networked together with a single hub Multiple hubs can be daisy chained together to allow networks of up to 14 controllers and a meter Refer to the HUB 1 and TriStar Meter ma...

Страница 28: ...nnect the TriStar MPPT 150V to other Morningstar controllers with the RSC 1 Serial to EIA 485 Adapter sold separately bridge an Ethernet connection through a TriStar MPPT 150V to an EIA 485 network Th...

Страница 29: ...for both scenarios is shown in figure 5 3 below Ethernet Cross over Cable Figure 5 3 Ethernet network diagrams Factory Default Network Settings DHCP enabled Live View Web Address http tsmppt serial nu...

Страница 30: ...ST BETWEEN ALL TERMINALS AND GROUND BEFORE TOUCHING AVERTISSEMENT RISQUE DE CHOC LETRIQUE NON ALIMENTATION OU AUX BORNES D ACCESSOIRES SONT ISOL S LEC TRIQUEMENT DE L ENTR E DE C C ET DOIT TRE ALIMENT...

Страница 31: ...not work Power is supplied to the 4 wire bus on the Power Ground lines The bus requires voltage in the range 8 16 Vdc All bus connections are secure and each terminal is wired in parallel line A to li...

Страница 32: ...Voltage All 150 Volts dc Battery Operating Voltage Range All 8 72 Volts dc Nominal Maximum Input Power 12 Volt 400 Watts 600 Watts 800 Watts 24 Volt 800 Watts 1200 Watts 1600 Watts 48 Volt 1600 Watts...

Страница 33: ...terminals Minimum wire size 0 25 mm2 24 AWG Maximum wire size 1 0 mm2 16 AWG Recommended torque 0 40 Nm 3 5 in lb Knockouts trade sizes M20 1 2 1 1 1 4 Mounting Vertical surface Environmental Operatin...

Страница 34: ...ter TriStar MPPT 24 Volt Efficiency output power Watts efficiency 99 98 97 96 95 94 93 92 91 90 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 0 89 33 Vmp 66 Vmp 98 Vmp 26 Vmp Batte...

Страница 35: ...t 30 C ambient temperature Ampacity for not more than three current car rying conductors in a raceway cable or earth buried 2 Voltage Drop Charts for 75 C Solid Copper Wire 1 Way Wire Distance feet 12...

Страница 36: ...at 30 C ambient temperature Ampacity for not more than three current car rying conductors in a raceway cable or earth buried 2 Voltage Drop Charts for 90 C Solid Copper Wire 1 Way Wire Distance feet 1...

Страница 37: ...005 EMC Immunity Industrial Environments EN 55022 2007 Class B EMC Emissions EN 60335 1 2002 Safety EN 60335 2 29 2005 Safety IEC 62109 1 2010 Safety of Power Converters in PV Systems TrisStar MPPTTM...

Отзывы: