67
TriStar MPPT Operator’s Manual
66
Specifications
Efficiency
TriStar MPPT 12 Volt Efficiency
output power (Watts)
efficienc
y (%)
98
97
96
95
94
93
92
91
90
89
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
0
88
16.5 Vmp
13 Vmp
66 Vmp
98 Vmp
Battery @ 12.8 V, 25 C ambient, firmware ver. 08 or later
TriStar MPPT 24 Volt Efficiency
output power (Watts)
efficienc
y (%)
99
98
97
96
95
94
93
92
91
90
100
200
300
400
500
600
700
800
900
1000 1100 1200 1300 1400 1500
0
89
33 Vmp
66 Vmp
98 Vmp
26 Vmp
Battery @ 25.6 V, 25 C ambient, firmware ver. 08 or later
TriStar MPPT 48 Volt Efficiency
output power (Watts)
efficienc
y (%)
100
99
98
97
96
95
94
93
92
91
200
400
600
800
1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
0
90
52 Vmp
66 Vmp
83 Vmp
98 Vmp
Battery @ 51.2 V, 25 C ambient, firmware ver. 08 or later