Manual mixer shower
16
1.1
Not enough cold water
flowing through shower.
1.2
Increase in the ambient
cold water temperature.
1.3
Cold water supply
blocked.
1.4
High volume of cold
water drawn off
elsewhere.
2.1
Not enough hot water
flowing through shower.
2.2
Decrease in the ambient
cold water temperature.
2.3
Insufficient hot water
supplies from the
heating system.
2.4
Hot water supply
blocked or restricted.
3.1
Water supplies cut off.
3.2
Blockage in pipework.
3.3
Sprayhead blocked.
3.4
System not capable
of supplying multiple
outlets at the
same time.
4.1
Running pressure in
excess of maximum
recommended.
5.1
Running pressure in
excess of maximum
recommended.
1.1.1
Turn the control lever anti-clockwise.
1.2.1
Turn turn control lever anti-clockwise.
1.3.1
Turn off shower and consult a competent
plumber or contact Customer Service.
1.4.1
Reduce the simultaneous demand from the
mains supply.
2.1.1
Turn the control lever clockwise.
2.2.1
Turn the control lever clockwise.
2.3.1
Make sure heating appliance is set to
maximum or has sufficient stored hot water.
2.3.2
Make sure heating appliance is igniting by
trying a hot water tap elsewhere.
2.4.1
Turn shower off and consult a competent
plumber or contact Triton Customer Service.
3.1.1
Check water elsewhere in house and if
necessary contact local water company.
3.2.1
Turn the shower off and consult a suitably
competent plumber.
3.3.1
Clean sprayhead.
3.4.1
Reduce the simultaneous demand.
3.4.2
Check stop or service valve is fully open.
3.4.3
Check if sufficient water pressure.
4.1.1
Fit a pressure reducing valve.
5.1.1
Fit a pressure reducing valve.
1
Water too hot.
2
Water too cold.
3
Water does not
flow or shower
pattern collapses
when another
outlet is
turned on.
4
Water too cold.
5
Shower controls
noisy while in
use.
The following can be carried out by a competent person
FAULT FINDING
Problem/Symptom Cause
Action/Cure