Manual mixer shower
10
FITTING THE BULKHEAD PIPEWORK
• Complete the outlet pipework ending in
a 15mm x ½" BSP female thread elbow
(fig.13)
or similar.
Note:
This fitting is not supplied, as variations
in installations require the selection of a suitable
solder or compression fitting.
• Screw the supplied male-thread connector
into the female fitting
(fig.14)
using PTFE
tape to give a watertight joint.
Note:
The male-thread connector supplied has
a shoulder. If fitting into a flush wall, make an
extra 8mm allowance for this shoulder at the
finished surface. The connector can be cut to size
if required.
• The threaded connector should protrude
from the finished wall surface between 8mm
and 13mm.
LEAK TESTING
• Fit a hose to the bulkhead threaded
connector and direct it to waste.
• Push the control lever down to close it. Open
the isolating valves to the shower. Open
the flow control by lifting the control lever
upwards and flush through.
• Turn the control fully to the left (HOT) and
then fully to the right (COLD).
• Push the control lever fully down to close off
the water supply.
• Check for any leaks and remedy if necessary.
• TURN OFF
the water supplies.
MAKING GOOD
Make good the incoming and outlet pipe
channelling and around the bulkhead outlet.
IMPORTANT:
When plastering around the
valve be sure to leave enough space to allow
access to the mixer for future servicing and/or
maintenance requirements.
DO NOT plaster the unit in place.
Make sure the grout lines are flush with the tiles
in order to provide a smooth sealing surface for
the outer cover.
8mm
−
13mm
Finished surface
Finished
surface
Fig.13
Fig.14
8mm - 13mm
Appropriate
fitting