16
3.
Remove any rubber plugs that may be present in the SFP module’s mouth.
4.
Align the fiber cable’s connector with the SFP module’s mouth and insert the
connector.
5.
Slide the connector in until a click is heard.
6.
If you want to pull the connector out, first push down the release clip on top of
the connector to release the connector from the SFP module.
To properly connect fiber cabling
:
Check that the fiber terminators are clean. You can
clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened
with a little ethanol. Dirty fiber terminators on fiber optic cables will impair the quality of
the light transmitted through the cable and lead to degraded performance on the port.
Note:
When inserting the cable, be sure the tab on the plug clicks into position to ensure
that it is properly seated.
Check the corresponding port LED on the Switch to be sure that the connection is valid.
(Refer to the LED chart).
3.2.
Installation
The location chosen for installing the Switch may greatly affect its performance. When
selecting, we recommend considering the following rules:
Install the Switch in an appropriate place. See Technical Specifications for the
acceptable temperature and humidity ranges.
Install the Switch in a location that is not affected by strong electromagnetic field
generators (such as motors), vibration, dust, and direct sunlight.
Leave at least 10cm of space at the front and rear of the unit for ventilation.
ATTENTION
The NGI-M05-C1 Series is an open type device and NGI-M05-C1 Series shall
be DIN-Rail mounted or wall mounted (optional) in cabinet or enclosure.
Hardware Installation
Step 1: Unpack the device and other contents of the package.
Step 2: Fasten DIN-Rail or Wall-mount kit on the rear of the NGI-M05-C1.
Содержание NGI-M05-C1
Страница 49: ...49 Refresh Click Refresh to begin configuring this screen afresh...
Страница 53: ...53 1000 full 1000Mbps Full duplex force mode 1000 full n 1000Mbps Full duplex auto negotiation mode...
Страница 62: ...62 Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh...
Страница 76: ...76 global state is enabled user must enable per VLAN states to enable the IGMP Snooping on the specific VLAN...
Страница 122: ...122...
Страница 125: ...125 Refresh Click Refresh to begin configuring this screen afresh...
Страница 151: ...151 Download Clicks the Download button to download all of the regisers information to load host...