78
AT.654252.409 ver.1.0
Troubleshooting manual
Replacing of an inverter current sensors.
A VSD must be de-energized and disconnected from a power supply.
Using a multimeter, make sure that there is no dangerous voltage on a DC-
link.
For unit disassembly you need next tool:
•
wrench size 10
mm (13/32”) —
1 pc;
•
wrench size 17
mm (11/16”)
—
2 pc;
•
flat screwdrive
r size 1.2 mm (3/64”) –
1 pc;
•
side cutter
–
1 pc;
•
cable tie
–
not less than 10 pcs.
In case if it is necessary to dismantle inverter current sensors:
Step 1. Remove electronic units panel
Remove electronic units panel shown on the figure 27:
1.
Disconnect all signal connectors from electronic units
2.
Uncrew four bolt shown on the figure 29
. Use wrench size 10 mm (13/32”).
Figure 27
–
Electronic units pantel
Electronic units panel