30
AT.654252.409 ver.1.2
Quickstart manual
Analog and Digital inputs/outputs
Description of different extension units
Extension units
USP MUSP Din8Dout4 AUSP
Numbers of digital inputs
6
4
8
0
Numbers of digital outputs
2
2
4
0
Numbers of analog inputs
6
4
0
8
Numbers of analog outputs
0
2
0
4
Example of extension connection
Note!
Expansion units are configured based on the required number of analog and
digital inputs / outputs specified in the order.
The configuration of the terminal block of external connections can be
changed based on the applied configuration of the expansion units
The terminal block for external connections
contains the name of the input and the name of
the extension unit to which it belongs.
«
Din0
»
–
Name of the input
«(
USP)
»
- Name of extension unit to which input belong
Configuration
Numbers of inputs/out-
puts
Din Dout Ain
Aout
USP
6
2
6
0
USP+AUSP+ Din8Dout4
14
6
14
4
USP+AUSP+ AUSP
6
2
24
8
USP+ Di Din8Dout4
24
10
6
0
MUSP
4
2
4
2
MUSP+AUSP+ Din8Dout4
12
6
12
6
MUSP+AUSP+ AUSP
4
2
22
8
MUSP+ Di Din8Dout4
20
10
4
2