TMCM-1311 TMCL Firmware V1.11 Manual (Rev. 1.17 / 2015-NOV-05)
75
www.trinamic.com
Number Axis Parameter Description
Range [Unit]
Acc.
175
Slope control
high side
Determines the slope of the motor driver
outputs.
Set to 2 or 3 for this module or
rather use the default value.
0: lowest slope
3: fastest slope
0… 3
RW
176
Slope control
low side
Determines the slope of the motor driver
outputs.
Set identical to slope control high
side.
0… 3
RW
177
Short protection
disable
0: Short to GND protection is on
1: Short to GND protection is disabled
Use default value!
0/1
RW
178
Short detection
timer
0: 3.2µs
1: 1.6µs
2: 1.2µs
3: 0.8µs
Use default value!
0… 3
RW
179
Vsense
Sense resistor voltage based current scaling
0: 0… 3A
1: 0… 1.5A
higher solution
0/1
RW
180
smartEnergy
actual current
This status value provides the
actual motor
current
setting as controlled by coolStep. The
value goes up to the CS value and down to the
portion of CS as specified by SEIMIN.
actual motor current scaling factor:
0 … 31: 1/32, 2/32, … 32/32
0… 31
RW
181
Stop on stall
Below this speed motor will not be stopped.
Above this speed motor will stop in case
stallGuard2 load value reaches zero.
0… +327.679.999
[pps]
RW
182
smartEnergy
threshold speed
Above this speed coolStep becomes enabled. 0… +327.679.999
[pps]
RW
183
smartEnergy
slow run current
Sets the motor current which is used below the
threshold speed.
0… 255
𝐼𝐼
𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝
=<
𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣
>×
4.2
𝐴𝐴
255
𝐼𝐼
𝑅𝑅𝑅𝑅𝑅𝑅
=<
𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣𝑣
>×
3
𝐴𝐴
255
RW
193
Ref. search mode
1 search left stop switch only
2 search right
stop switch, then search left
stop switch
3 search right stop switch, then search left stop
switch from both sides
4 search left stop switch from both sides
5 search home switch in negative direction,
reverse the direction when left stop switch
reached
6 search home switch in positive direction,
reverse the direction when right stop switch
reached
7 search home switch in positive direction,
ignore end switches
8 search home switch in negative direction,
ignore end switches
Adding 128 to these values reverses the
polarity of the home switch input.
1… 8
RWE
194
Referencing
search speed
For the reference search this value directly
specifies the search speed.
327.678.000…
+327.679.999
[pps]
RWE