Number Global parameter
Description
Range
Access
69
CAN bit rate
2
20kBit/s
3
50kBit/s
4
100kBit/s
5
125kBit/s
6
250kBit/s
7
500kBit/s
8
1000kBit/s
Default
2… 8
RWE
70
CAN reply ID
The CAN ID for replies from the board (default: 2)
0… 7ff
RWE
71
CAN ID
The module (target) address for CAN (default: 1)
0… 7ff
RWE
73
configuration
EEPROM lock flag
Write: 1234 to lock the EEPROM, 4321 to unlock it.
Read: 1=EEPROM locked, 0=EEPROM unlocked.
0/1
RWE
75
Telegram pause time Pause time before the reply via RS485 is sent.
For RS485 it is often necessary to set it to 15 (for
RS485 adapters controlled by the RTS pin).
For CAN interface this parameter has no effect!
0… 255
RWE
76
Serial host address
Host address used in the reply telegrams sent back
via RS485.
0… 255
RWE
77
Auto start mode
0: Do not start TMCL application after power up
(default).
1: Start TMCL application automatically after power
up.
0/1
RWE
79
End switch polarity
0: normal polarity
1: reverse polarity
0/1
RWE
81
TMCL code
protection
Protect a TMCL program against disassembling or
overwriting.
0 – no protection
1 – protection against disassembling
2 – protection against overwriting
3 – protection against disassembling and overwriting
If you switch off the protection against
disassembling, the program will be erased first!
Changing this value from 1 or 3 to 0 or 2, the
TMCL program will be wiped off.
0,1,2,3
RWE
83
CAN secondary
address
Second CAN ID for the module. Switched off when
set to zero.
0… 7ff
RWE
84
Coordinate storage
0 – coordinates are stored in the RAM only (but can
be copied explicitly between RAM and EEPROM)
1 – coordinates are always stored in the EEPROM only
0 or 1
RWE
85
do not restore user
variables
0 – user variables are restored (
default
)
1 – user variables are not restored
0/1
RWE
88
Interface selection
0 – RS485 interface
1 – CAN interface
0/1
RWE
128
TMCL application
status
0 –stop
1 – run
2 – step
3 – reset
0… 3
R
129
Download mode
0 – normal mode
1 – download mode
0/1
R
130
TMCL program
counter
The index of the currently executed TMCL instruction.
R
132
Tick timer
A 32 bit counter that gets incremented by one every
millisecond. It can also be reset to any start value.
RW
133
Random number
Choose a random number.
Read only!
0…
2147483647
R