TMCM-1311 TMCL Firmware V1.11 Manual (Rev. 1.17 / 2015-NOV-05)
46
www.trinamic.com
5.7.19
JA (jump always)
Jump to a fixed address in the TMCL program memory.
This command is intended only for standalone operation.
Internal function:
the TMCL program counter is set to the passed value.
Related commands:
JC, WAIT, CSUB
Mnemonic:
JA <Label>
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
22
don’t care
don’t care
<jump address>
Example:
An infinite loop in TMCL™
Loop: MVP ABS, 0, 10000
WAIT POS, 0, 0
MVP ABS, 0, 0
WAIT POS, 0, 0
JA Loop
//Jump to the label Loop
Binary format of JA Loop assuming that the label Loop is at address 20:
Byte Index
0
1
2
3
4
5
6
7
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Value (hex)
$01
$16
$00
$00
$00
$00
$00
$14