Number
Axis Parameter
Description
Range [Units]
Access
168
SmartEnergy
current
minimum
(SEIMIN)
Sets the lower motor current limit for CoolStep
operation by scaling the maximum current (see
axis parameter 6) value.
Minimum motor current:
0 -
1
2
of CS
1 -
1
4
of CS
0/1
RW
169
SmartEnergy
current down
step
Sets the number of StallGuard2 readings above
the upper threshold necessary for each current
decrement of the motor current. Number of
StallGuard2 measurements per decrement:
Scaling: 0. . . 3: 32, 8, 2, 1
0: slow decrement
3: fast decrement
0. . . 3
RW
170
SmartEnergy
hysteresis
Sets the distance between the lower and the
upper threshold for StallGuard2 reading. Above
the upper threshold the motor current becomes
decreased. Hysteresis:
([
AP
172] + 1)
∗
32
Upper StallGuard threshold:
([
AP
172]+[
AP
170]+
1)
∗
32
0. . . 15
RW
171
SmartEnergy
current up step
Sets the current increment step. The current
becomes incremented for each measured Stall-
Guard2 value below the lower threshold see
SmartEnergy hysteresis start).
Current incre-
ment step size:
Scaling: 0. . . 3: 1, 2, 4, 8
0: slow increment
3: fast increment / fast reaction to rising load
0. . . 3
RW
172
SmartEnergy
hysteresis start
The lower threshold for the StallGuard2 value
(see SmartEnergy current up step).
0..15
RW
173
StallGuard2
filter enable
Enables the StallGuard2 filter for more precision
of the measurement. If set, reduces the mea-
surement frequency to one measurement per
four fullsteps. In most cases it is expedient to
set the filtered mode before using CoolStep. Use
the standard mode for step loss detection.
0 - standard mode
1 - filtered mode
0/1
RW
174
StallGuard2
threshold
This signed value controls StallGuard2 threshold
level for stall output and sets the optimum mea-
surement range for readout. A lower value gives
a higher sensitivity. Zero is the starting value.
A higher value makes StallGuard2 less sensitive
and requires more torque to indicate a stall.
-64. . . +63
RW