TMCM-6212 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.07 • 2019-JAN-25
36 / 140
3.6.11
RFS (Reference Search)
The TMCM-6212 has a built-in reference search algorithm. The reference search algorithm provides
different refrence search modes. This command starts or stops the built-in reference search algorithm.
The status of the reference search can also be queried to see if it already has finished. (In a TMCL program
it mostly is better to use the WAIT RFS command to wait for the end of a reference search.) Please see the
appropriate parameters in the axis parameter table to configure the reference search algorithm to meet
your needs (please see chapter
Internal function:
The internal reference search state machine is started or stoped, or its state is queried.
Related commands:
SAP, GAP, WAIT.
Mnemonic:
RFS <START|STOP|STATUS>, <motor>
Binary Representation
Instruction
Type
Motor/Bank
Value
0 START — start reference search
13
1 STOP — stop reference search
0. . . 5
0 (don’t care)
2 STATUS — get status
Reply in Direct Mode (RFS START or RFS STOP)
Status
Value
100 - OK
0 (don’t care)
Reply in Direct Mode (RFS STATUS)
Status
Value
100 - OK
0
no ref. search active
other values
reference search active
Example
Start reference search of motor 0.
Mnemonic:
RFS START, 0.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.