The factory default IP address for the EAS Network Receiver is “10.1.65.79”. By default it
monitors port 59910 for a connection from the EAS Network Receiver Management Software.
Those familiar with networking may be able to install the configuration software and configure the
instrument over the network, bypassing the following procedure.
Perform the following steps to complete the initial configuration of the EAS Network Receiver:
1. Connect the RS-232 cable (supplied) between the
Network Receiver’s RS-232 port and a PC with an
RS-232 port and HyperTerminal software.
2. Start a HyperTerminal session for the serial port (COM 1)
that the Network Receiver has been connected to on a
laptop or PC.
4.
Initial Configuration
!
4
Note:
HyperTerminal is used for illustration purposes only, any terminal
emulator will work with this setup procedure.
3. Configure the port setting properties for the
HyperTerminal session as follows;
•
Bits per second:
9600 Baud
•
Data bits:
8
•
Parity:
None
•
Stop bits:
1
•
Flow control:
None