Fig. No 3 Parameter setting of the program “Hyper Terminal”
Couple ports of the receiver and programing device via programing cable and
activate the program. Set parameters of the communication with the program: Data
exchange speed of the port the device is connected to: 9600b/s, data bits: 8, parity:
none, stop bit:1 , Flow control: none (see fig. 3).
Switch on the power supply of the programing device and press RESET button
on the board of the router. If everything is performed properly version of the device is
displayed on the monitor together with the note “Password”; yellow LED lights on the
board of the router.
RM1 - 60619
SN
Password:
Enter the password to gain access to exploitation parameters setting menu.
In order to change password press the key [P] and follow commands shown on
the monitor.
RM1 - 60619
SN
>1.Connections
setting of the reception module’s parameters;
2. Receiver 01
Device number setting;
>3. Line
reception channel number setting;
4. RS-232C Speed
setting of the speed of serial port;
Parameters, labelled “
>
” has separate setting windows, these labeled “*” – are
switched on/off.
Settings are performed via numerical keys of the keyboard. For example: in order
to change parameter 3, press the key [3] and if it is necessary to enter its value, the note
[Value] is displayed. Then value of the parameter is entered and confirmed by pressing
the key [Enter].
If it is necessary to change exploitation parameters of the module setting of the
parameters of the reception modules is used if without taking them out of the receiver.
The number of the device is changed if centralized monitoring station contains a
lot of devices used together with a single centralized monitoring program and if it is
necessary to recognize the receiver the information is obtained from.
TRIKDIS
Draugystės g. 17, LT-51229 Kaunas, Lietuva, tel. 8-37-408040, faks. 8-37-760554
el. paštas:
,
www.trikdis.lt
11