Centralized monitoring program, which receives messages being sent via
Surgard MRL2-DG protocol, is used for data processing. Structure of output signals is
presented in annex A.
After interconnection of PC and the receiver and activation of the centralized
monitoring program, received messages are transmitted to PC for further processing.
The receiver constantly controls communication with the PC. Upon trouble or
disconnection of PC, the receiver switches to autonomous operation mode. All received
messages are displayed on the monitor and stored.
Received messages are displayed together with comments on the event, stored
in the data base of the program, and according to the order set to the staff, registration
is performed. The event may be registered according to time of the receiver or the
program. Detailed process concerning work with the program is described in user
manual of the program.
A Annex
OUTPUT TO THE CENTRALIZED MONITORING PROGRAM
SURGARD MRL2-DG
Heartbeats
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
r
r
l
s
s
s
s
s
s
s
s
s
s
s
@
s
s
s
s
#
Title
Explanation
1
Protocol No
1
2-3
Receiver’s No
Possible No 1 to 99
4
Line number
Line number
5-15
Space
11 spaces
16
Symbol
@ symbol
17-20
Space
4 spaces
SURGARD MRL2-DG
Ademco Contact ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
5
r
r
l
s
1
8
a
a
a
a
Q
X
Y
Z
G
G
C
C
C
#
Title
Explanation
1
Protocol No
5
2-3
Receiver’s No
Possible No 1 to 99
4
Line number
Line number
5
Space
space
6-7
18
Ademco Contact ID format No
8-11
Object No
Object No 4 symbols
12
Event sizer
E – new alarm or opening,
R – new restoration or closure,
P – delayed message
13-15
XYZ
Event code
16-17
GG
Group No
TRIKDIS