Key features and description of operation 

The   multichannel   receiver   RI-4010M   receives   and   recognizes   messages   of 

subscription   modules   being   sent   via   various   communication   channels.   Selected 
communication channel type defines type of appropriate built –in module. 

The reception module ensures recognition of the messages being sent as well as 

their filtration according to exploitation parameters, having been set during programing, 
and transmission of information to the platform of the multichannel receiver. 

The   platform   of   the   multichannel  receiver   RI-4010M   ensures   reception  of   the 

information   from   the   built-in   reception   modules,   its   transmission   to   the   centralized 
monitoring station, printing and indication of received messages. 

The   multichannel   receiver   has   been   regularized   for   data   transmission   to   the 

centralized monitoring programs, recognizing Surgard protocol. The printer connected to 
the receiver in sequence prints each received message. If monitoring program or the 
printer is not connected, the messages are accumulated at the internal memory of the 
receiver (about 1000 latest messages) and will be transmitted as soon as the devices 
will be connected and activated. 

The multichannel receiver operates autonomously, displays received messages 

together with a sound. Control buttons of the receiver may help to select monitoring type 
of received messages. Messages from all channels or only from a single channel can be 
observed   by   transmitting   all   received   messages   to   the   monitoring   program 
simultaneously. 

The platform of the multichannel receiver RI-4010M may contain built-in industrial 

computer with installed centralized monitoring program. 

Built-in   power   supply   source   ensures   constant   voltage   in   all   nodes   of   the 

multichannel   receiver,   charges   backup   battery   and   keeps   it   ready   for   operation.   In 
secondary   circuits   the   power   supply   source   has   high   speed   protection   from   short 
connection.   Upon   outage   of   alternating   voltage   network,   the   receiver   automatically 
switches to the backup battery. LED inform about power supply status. By necessity, 
external direct voltage power supply source might be connected. 

Specifications

1.   Seven   reception   modules,   operating   via   different   communication   channels, 

may be built in the multichannel receiver RI-4010M: 

GSM reception module RG1 for data transmitting via GSM voice channel; 

GSM reception module RG2 for data transmitting via SMS message;

GSM reception module RG3 for data transmitting via GPRS voice channel; 

Telephonic   reception   module   RT2   for   data   transmitting   via   wired 
communication channel; 

Reception module RS232 ensures data reception from other devices; 

TRIKDIS

Draugystės g. 17, LT-51229   Kaunas, Lietuva, tel. 8-37-408040, faks. 8-37-760554

el. paštas: 

[email protected]

 , 

www.trikdis.lt

 

5

Содержание RI-4010M

Страница 1: ...JOINT STOCK COMPANY MULTICHANNEL RECEIVER RI 4010M version RM1 60619 User guide...

Страница 2: ...age of AC 50 1 Hz frequency network and from 12 V backup battery capacitance of which 7Ah Permissible voltage alteration range is 10 Current from the network does not exceed 0 15 A The receiver may be...

Страница 3: ...ng of the multichannel receiver and preparation to work 10 Setting of exploitation parameters 10 Work with the multichannel receiver without PC 12 Work with the multichannel receiver by using software...

Страница 4: ...ion control and indication bodies connectors and reception modules which ensure signal reception via various communication channels Seven reception modules are available to be built in the platform of...

Страница 5: ...of the receiver about 1000 latest messages and will be transmitted as soon as the devices will be connected and activated The multichannel receiver operates autonomously displays received messages tog...

Страница 6: ...abellin g Parameter Meaning GSM reception module RG1 for data transmission via GSM voice channel 40 4F Radio engineering parameters in compliance with standard requirements GSM reception module RG2 fo...

Страница 7: ...requirements EN 300 113 Sensitivity not worse than 0 3 V Input resistance 50 Received encoded messages RAS 2M LARS LARS1 Configurated information filters according to Time Object number Communication...

Страница 8: ...intains indicated parameters at the air temperature from 10 C to 55 C and relative humidity up to 90 near 20 C 10 Overall dimensions of the receiver do not exceed 450x95x400 mm 11 Mass without set in...

Страница 9: ...annel receiver Operation mode of the receiver is set with the help of control buttons to the left to the right V Down Up exit without changing anything confirm changes and exit Layout of external conn...

Страница 10: ...d Some of the exploitation parameters of the receiver may be changed using programing device SPROG 1 and the program Hyper Terminal Connect AC network to the multichannel receiver via special cable an...

Страница 11: ...ion module s parameters 2 Receiver 01 Device number setting 3 Line reception channel number setting 4 RS 232C Speed setting of the speed of serial port Parameters labelled has separate setting windows...

Страница 12: ...In order to confirm the option press Note TIME SET will be displayed and the receiver will return to Menu Window Back to normal indication mode press In the same way date of the receiver is set althou...

Страница 13: ...the program Detailed process concerning work with the program is described in user manual of the program A Annex OUTPUT TO THE CENTRALIZED MONITORING PROGRAM SURGARD MRL2 DG Heartbeats 1 2 3 4 5 6 7 8...

Страница 14: ...s 15 16 XX SIA event code 17 20 CCCC Zone number SURGARD MRL2 DG Ademco Express 4 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 r r l s s s s a a a a a a s s s s C C Title Explanation 1 Proto...

Страница 15: ...er supply connector Contact Description 1 Negative terminal 0 V 2 Positive terminal 12 V 3 Free 4 Grounding terminal TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el...

Страница 16: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 16...

Страница 17: ...EGISTERED B0 Modem has registered in GSM network GSM UNREGISTERED B1 Modem failed to register in GSM network GPRS CONNECTED B2 GPRS server connected RG3 only GPRS DISCONNECTED B3 GPRS server disconnec...

Страница 18: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 18...

Страница 19: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 19...

Отзывы: